Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification
arXiv:1103.4426 · doi:10.1364/OL.36.001479
Abstract
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 hertz.
arXiv commentTo be published in Optics Letters
References in corpus (5)
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Test of the Equivalence Principle Using a Rotating Torsion Balance
- Short-range tests of the equivalence principle
- Optimizing the Signal to Noise Ratio of a Beam Deflection Measurement with Interferometric Weak Values
- Interferometric weak value deflections: quantum and classical treatments
Cited by in corpus (29)
- Colloquium: Understanding Quantum Weak Values: Basics and Applications
- Nonperturbative theory of weak pre- and post-selected measurements
- Technical advantages for weak value amplification: When less is more
- The significance of the imaginary part of the weak value
- Weak Value Amplification Can Outperform Conventional Measurement in the Presence of Detector Saturation
- Experimentally quantifying the advantages of weak-value-based metrology
- Improving the precision of weak measurements by postselection measurement
- Entanglement-assisted weak value amplification
- Weak-value amplification and optimal parameter estimation in the presence of correlated noise
- Strengthening weak value amplification with recycled photons
- Quantum circuits for measuring weak values, Kirkwood--Dirac quasiprobability distributions, and state spectra
- Optimal Probe Wavefunction of Weak-Value Amplification
- Weak-value amplification as an optimal metrological protocol
- Protecting weak measurements against systematic errors
- Classical Field Approach to Quantum Weak Measurements
- Ultrasensitive Inverse Weak-Value Tilt Meter
- Interferometric evanescent wave excitation of nano-antenna for ultra-sensitive displacement and phase metrology
- Casimir torque between nanostructured plates
- Weak-value-amplification analysis beyond the AAV limit of weak measurements
- Suppressing technical noises in weak measurement by entanglement
- Refraction of light by light in vacuum
- The DeLLight experiment to observe an optically-induced change of the vacuum index
- Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
- Practical Advantages of Almost-Balanced-Weak-Values Metrological Techniques
- Implementing generalized measurements with superconducting qubits
- Progress and Perspectives on Weak-value Amplification
- Quantum logical entropy: fundamentals and general properties
- Dual to the anomalous weak value effect of photon-polarisation separation
- Time-symmetry and topology of the Aharonov-Bohm effect