Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors
arXiv:1507.04151 · doi:10.1109/TMTT.2016.2544303
Abstract
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per readout line. We describe a novel readout system for large arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout, which is a combination of a digital front- and back-end and an analog up- and down-converter system, can read out up to 4000 detectors simultaneously with 1 kHz datarate. The system achieves a readout noise power spectral density of -98 dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN MKIDs can be read out without deteriorating their intrinsic performance.
7 pages, 7 figures
References in corpus (3)
- High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
- Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
- Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
Cited by in corpus (38)
- A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
- Demonstration of a Thermally-Coupled Row-Column SNSPD Imaging Array
- Mitigation of Cosmic Ray Effect on Microwave Kinetic Inductance Detector Arrays
- Superconducting NbTiN Thin Films with Highly Uniform Properties over a 100 mm diameter Wafer
- First light demonstration of the integrated superconducting spectrometer
- An Open Source, FPGA-based LeKID readout for BLAST-TNG: Pre-flight Results
- The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
- Exploring Cosmic Origins with CORE: The Instrument
- SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
- Wideband on-chip terahertz spectrometer based on a superconducting filterbank
- Characterising the Performance of High-Speed Data Converters for RFSoC-based Radio Astronomy Receivers
- Detectors and cooling technology for direct spectroscopic biosignature characterization
- Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
- Demonstration of microwave multiplexed readout of DC biased superconducting nanowire detectors
- Terahertz Band-Pass Filters for Wideband Superconducting On-chip Filter-bank Spectrometers
- Suppression of radiation loss in high kinetic inductance superconducting co-planar waveguides
- Thermal Kinetic Inductance Detectors for millimeter-wave detection
- Dispersive readout of molecular spin qudits
- Hydrogenated Amorphous Silicon Carbide: A Low-loss Deposited Dielectric for Microwave to Submillimeter Wave Superconducting Circuits
- Prime-Cam: A first-light instrument for the CCAT-prime telescope
- Phonon and light read out of a LiMoO crystal with multiplexed kinetic inductance detectors
- Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility
- Development of dual-polarization LEKIDs for CMB observations
- Utilization of the Superconducting Transition for Characterizing Low-Quality-Factor Superconducting Resonators
- Complex beam mapping and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera
- Operation of Multi-Pixel Radio-Frequency Superconducting Nanowire Single-Photon Detector Arrays
- Eliminating stray radiation inside large area imaging arrays
- A Scalable Cryogenic LED Module for Selectively Illuminating Kinetic Inductance Detector Arrays
- Characterization of two-level system noise for microwave kinetic inductance detector comprising niobium film on silicon substrate
- A measurement method for responsivity of microwave kinetic inductance detector by changing power of readout microwaves
- Magnetic field sensing with the kinetic inductance of a high- superconductor
- Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array
- Demonstration of Ultra-Sensitive KIDs for Future THz Space Borne Polarimeters
- Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy
- Simulating the radiation loss of superconducting submillimeter wave filters and transmission lines using Sonnet EM
- The Galaxy Evolution Probe
- GLTCAM: Concept of Multi-color Millimeter and Submillimeter Camera for the Greenland Telescope
- Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors