Mitigation of Cosmic Ray Effect on Microwave Kinetic Inductance Detector Arrays
arXiv:1901.02387 · doi:10.1063/1.5052419
Abstract
For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an important requirement for detectors to be used in future space missions. In order to investigate possible solutions, we carry out a systematic study by testing four large arrays of Microwave Kinetic Inductance Detectors (MKIDs), each consisting of 960 pixels and fabricated on monolithic 55 mm 55 mm 0.35 mm Si substrates. We compare the response to cosmic ray interactions in our laboratory for different detector arrays: A standard array with only the MKID array as reference; an array with a low superconducting film as phonon absorber on the opposite side of the substrate; and arrays with MKIDs on membranes. The idea is that the low layer down-converts the phonon energy to values below the pair breaking threshold of the MKIDs, and the membranes isolate the sensitive part of the MKIDs from phonons created in the substrate. We find that the dead time can be reduced up to a factor of 40 when compared to the reference array. Simulations show that the dead time can be reduced to below 1 % for the tested detector arrays when operated in a spacecraft in an L2 or a similar far-Earth orbit. The technique described here is also applicable and important for large superconducting qubit arrays for future quantum computers.
arXiv comment5 pages, 4 figures; accepted to APL
References in corpus (13)
- Surface codes: Towards practical large-scale quantum computation
- Majorana qubit decoherence by quasiparticle poisoning
- Fluctuations in the electron system of a superconductor exposed to a photon flux
- A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
- Planck 2013 results X. Energetic particle effects: characterization, removal, and simulation
- High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
- Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors
- Excitation of superconducting qubits from hot non-equilibrium quasiparticles
- Non-equilibrium superconductivity in superconducting resonators
- Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
- Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz
- Lumped Element Kinetic Inductance Detectors for space applications
- Estimate of the impact of background particles on the X-Ray Microcalorimeter Spectrometer on IXO
Cited by in corpus (38)
- Exponential suppression of bit or phase flip errors with repetitive error correction
- Materials loss measurements using superconducting microwave resonators
- Resolving catastrophic error bursts from cosmic rays in large arrays of superconducting qubits
- Reducing the impact of radioactivity on quantum circuits in a deep-underground facility
- Two-level systems in superconducting quantum devices due to trapped quasiparticles
- Phonon traps reduce the quasiparticle density in superconducting circuits
- Scalable High-Performance Fluxonium Quantum Processor
- Interplay between kinetic inductance, non-linearity and quasiparticle dynamics in granular aluminum MKIDs
- Engineering superconducting qubits to reduce quasiparticles and charge noise
- Implementation of a transmon qubit using superconducting granular aluminum
- Phonon downconversion to suppress correlated errors in superconducting qubits
- TLS Dynamics in a Superconducting Qubit Due to Background Ionizing Radiation
- Anomalous Charge Noise in Superconducting Qubits
- Phonon-trapping enhanced energy resolution in superconducting single photon detectors
- 2023 Astrophotonics Roadmap: pathways to realizing multi-functional integrated astrophotonic instruments
- The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
- Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes
- Kinetic Inductance Detectors for the OLIMPO experiment: in--flight operation and performance
- Mitigation of quasiparticle loss in superconducting qubits by phonon scattering
- Modeling phonon-mediated quasiparticle poisoning in superconducting qubit arrays
- Operating in a deep underground facility improves the locking of gradiometric fluxonium qubits at the sweet spots
- Thermal Kinetic Inductance Detectors for millimeter-wave detection
- LEKID sensitivity for space applications between 80 and 600 GHz
- In-flight performance of the LEKIDs of the OLIMPO experiment
- Active quasiparticle suppression in a non-equilibrium superconductor
- Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation
- Understanding and minimizing resonance frequency deviations on a 4-inch kilo-pixel kinetic inductance detector array
- Cosmic muon flux attenuation methods for superconducting qubit experiments
- Flip-chip-based fast inductive parity readout of a planar superconducting island
- A self-calibrating superconducting pair-breaking detector
- Material matters in superconducting qubits
- Performance of Superconducting Resonators Suspended on SiN Membranes
- Correlated frequency noise in a multimode acoustic resonator
- Cosmic ray susceptibility of the Terahertz Intensity Mapper detector arrays
- Recombination of localized quasiparticles in disordered superconductors
- Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors
- Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors
- Strong Reduction of Quasiparticle Fluctuations in a Superconductor due to Decoupling of the Quasiparticle Number and Lifetime