Detectors and cooling technology for direct spectroscopic biosignature characterization
arXiv:1607.05708 · doi:10.1117/1.JATIS.2.4.041212
Abstract
Direct spectroscopic biosignature characterization (hereafter "biosignature characterization") will be a major focus for future space observatories equipped with coronagraphs or starshades. Our aim in this article is to provide an introduction to potential detector and cooling technologies for biosignature characterization. We begin by reviewing the needs. These include nearly noiseless photon detection at flux levels as low as in the visible and near-IR. We then discuss potential areas for further testing and/or development to meet these needs using non-cryogenic detectors (EMCCD, HgCdTe array, HgCdTe APD array), and cryogenic single photon detectors (MKID arrays and TES microcalorimeter arrays). Non-cryogenic detectors are compatible with the passive cooling that is strongly preferred by coronagraphic missions, but would add non-negligible noise. Cryogenic detectors would require active cooling, but in return deliver nearly quantum limited performance. Based on the flight dynamics of past NASA missions, we discuss reasonable vibration expectations for a large UV-Optical-IR space telescope (LUVOIR) and preliminary cooling concepts that could potentially fit into a vibration budget without being the largest element. We believe that a cooler that meets the stringent vibration needs of a LUVOIR is also likely to meet those of a starshade-based Habitable Exoplanet Imaging Mission.
arXiv comment31 pages, 6 figures, and 4 tables. Submitted to the Journal of Astronomical Telescopes, Instruments, and Systems
References in corpus (11)
- Spectral Evolution of an Earth-Like Planet
- ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
- Planck Early Results. II. The thermal performance of Planck
- Lower Limits on Aperture Size for an ExoEarth-Detecting Coronagraphic Mission
- Identifying Planetary Biosignature Impostors: Spectral Features of CO and O4 Resulting from Abiotic O2/O3 Production
- Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors
- Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors
- Prospects for Detecting Oxygen, Water, and Chlorophyll on an Exo-Earth
- From Cosmic Birth to Living Earths: The Future of UVOIR Space Astronomy
- Technology advancement of the CCD201-20 EMCCD for the WFIRST coronagraph instrument: sensor characterization and radiation damage
- ATLAST detector needs for direct spectroscopic biosignature characterization in the visible and near-IR
Cited by in corpus (11)
- Early evolution of purple retinal pigments on Earth and implications for exoplanet biosignatures
- Circuit designs for superconducting optoelectronic loop neurons
- Space Technology for Directly Imaging and Characterizing Exo-Earths
- Superconducting Optoelectronic Neurons I: General Principles
- Multi-Amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy
- Baseline Requirements For Detecting Biosignatures with the HabEx and LUVOIR Mission Concepts
- Optimizing Charge-coupled Device Readout Enabled by the Floating-Gate Amplifier
- Pyxel: the collaborative detection simulation framework
- Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors
- Improving the energy resolution of photon counting Microwave Kinetic Inductance Detectors using principal component analysis
- The largest cognitive systems will be optoelectronic