Abstract
Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD's floating-gate amplifiers to optimize the correlated double sampling (CDS) by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD's structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e rms pix at 19 s pix for a single charge measurement per pixel - simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.
9 pages, 7 figures, accepted for publication in PASP
References in corpus (14)
- SciPy 1.0--Fundamental Algorithms for Scientific Computing in Python
- Astropy: A Community Python Package for Astronomy
- The Astropy Project: Building an inclusive, open-science project and status of the v2.0 core package
- The Astropy Project: Sustaining and Growing a Community-oriented Open-source Project and the Latest Major Release (v5.0) of the Core Package
- The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument
- SENSEI: Direct-Detection Constraints on Sub-GeV Dark Matter from a Shallow Underground Run Using a Prototype Skipper-CCD
- First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons
- SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
- Detectors and cooling technology for direct spectroscopic biosignature characterization
- Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device
- Characterization of Skipper CCDs for Cosmological Applications
- Sixteen Multiple-Amplifier Sensing Charge-Coupled Devices and Characterization Techniques Targeting the Next Generation of Astronomical Instruments
- Multi-Amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy
- Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement