Multi-Amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy
arXiv:2406.06472 · doi:10.1088/1538-3873/ad716c
Abstract
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the DESI CCD controller, we report a read noise of 1.03 e rms/pix at a speed of 26 s/pix with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from 300 to 35,000 e was also measured to be . We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.
21 pages, 18 figures, accepted to PASP
References in corpus (26)
- SciPy 1.0--Fundamental Algorithms for Scientific Computing in Python
- Astropy: A Community Python Package for Astronomy
- The Astropy Project: Building an inclusive, open-science project and status of the v2.0 core package
- The Dark Energy Camera
- Single-electron and single-photon sensitivity with a silicon Skipper CCD
- The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument
- Target Selection and Validation of DESI Luminous Red Galaxies
- SENSEI: Direct-Detection Constraints on Sub-GeV Dark Matter from a Shallow Underground Run Using a Prototype Skipper-CCD
- SENSEI: First Direct-Detection Constraints on sub-GeV Dark Matter from a Surface Run
- Target Selection and Validation of DESI Quasars
- Lower Limits on Aperture Size for an ExoEarth-Detecting Coronagraphic Mission
- Absolute measurement of the Fano factor using a Skipper-CCD
- SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD
- Instrumental response model and detrending for the Dark Energy Camera
- Radiation Tolerance of Fully-Depleted P-Channel CCDs Designed for the SNAP Satellite
- Detectors and cooling technology for direct spectroscopic biosignature characterization
- Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection
- Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
- Quantum efficiency modeling for a thick back-illuminated astronomical CCD
- Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device
- Characterization of Skipper CCDs for Cosmological Applications
- Space Technology for Directly Imaging and Characterizing Exo-Earths
- Low-energy reactor neutrino physics with the CONNIE experiment
- Characterization of a photon counting EMCCD for space-based high contrast imaging spectroscopy of extrasolar planets
- Crosstalk in multi-output CCDs for LSST
- Wide-field Multi-object Spectroscopy to Enhance Dark Energy Science from LSST