Absolute calibration of a wideband antenna and spectrometer for sky noise spectral index measurements
arXiv:1209.1106 · doi:10.1029/2011RS004962
Abstract
A new method of absolute calibration of sky noise temperature using a three-position switched spectrometer, measurements of antenna and low noise amplifier impedance with a vector network analyzer, and ancillary measurements of the amplifier noise waves is described. The details of the method and its application to accurate wideband measurements of the spectral index of the sky noise are described and compared with other methods.
15 pages, 10 figures, published in Radio Science
References in corpus (3)
Cited by in corpus (48)
- An absorption profile centred at 78 megahertz in the sky-averaged spectrum
- Hydrogen Epoch of Reionization Array (HERA)
- The Giant Radio Array for Neutrino Detection (GRAND): Science and Design
- Data Analysis for Precision 21 cm Cosmology
- Design and characterization of the Large-Aperture Experiment to Detect the Dark Age (LEDA) radiometer systems
- Bayesian constraints on the global 21-cm signal from the Cosmic Dawn
- Results from EDGES High-Band: I. Constraints on Phenomenological Models for the Global cm Signal
- The REACH radiometer for detecting the 21-cm hydrogen signal from redshift 7.5 to 28
- SARAS: a precision system for measurement of the Cosmic Radio Background and signatures from the Epoch of Reionization
- SARAS 2: A Spectral Radiometer for probing Cosmic Dawn and the Epoch of Reionization through detection of the global 21 cm signal
- Calibration of the EDGES High-Band Receiver to Observe the Global 21-cm Signature from the Epoch of Reionization
- Improved Measurement of the Spectral Index of the Diffuse Radio Background Between 90 and 190 MHz
- Spectral Index of the Diffuse Radio Background Between 50 and 100 MHz
- Limits on Foreground Subtraction from Chromatic Beam Effects in Global Redshifted 21 cm Measurements
- Mapper of the IGM spin temperature: instrument overview
- Results from EDGES High-Band: II. Constraints on Parameters of Early Galaxies
- Assessment of the Projection-induced Polarimetry Technique for Constraining the Foreground Spectrum in Global 21 cm Cosmology
- Radiometric Measurements of Electron Temperature and Opacity of Ionospheric Perturbations
- Bayesian noise wave calibration for 21-cm global experiments
- A Bayesian Calibration Framework for EDGES
- Absolute Calibration of Diffuse Radio Surveys at 45 and 150 MHz
- Lunar occultation of the diffuse radio sky: LOFAR measurements between 35 and 80 MHz
- One-Port Direct/Reverse Method for Characterizing VNA Calibration Standards
- Cold-Source Noise Measurement of a Differential Input Single-Ended Output Low-Noise Amplifier Connected to a Low-Frequency Radio Astronomy Antenna
- The effects of the antenna power pattern uncertainty within a global 21 cm experiment
- Calibration Error in 21-centimeter Global Spectrum Experiments
- RHINO: A large horn antenna for detecting the 21cm global signal
- Receiver design for the REACH global 21-cm signal experiment
- Effects of model incompleteness on the drift-scan calibration of radio telescopes
- Generalized Formalisms of the Radio Interferometer Measurement Equation
- Measuring Noise Parameters Using an Open, Short, Load, and 1/8-wavelength Cable as Source Impedances
- A High Sensitivity Fourier Transform Spectrometer for Cosmic Microwave Background Observations
- RFSoC receiver calibration system for 21-cm global spectrum experiments from space: The CosmoCube case
- Improvements to the Search for Cosmic Dawn Using the Long Wavelength Array
- A Bayesian approach to modelling spectrometer data chromaticity corrected using beam factors -- II. Model priors and posterior odds
- Low-Frequency Radio Recombination Lines Away From the Inner Galactic Plane
- Optimization of Antenna Performance for Global 21-cm Observations and Verification Using Scaled Copies
- Accounting for Noise and Singularities in Bayesian Calibration Methods for Global 21-cm Cosmology Experiments
- Singular spectrum analysis of time series data from low frequency radiometers, with an application to SITARA data
- Forecast measurement of the 21 cm global spectrum from Lunar orbit with the Vari-Zeroth-Order Polynomial (VZOP) method
- Practical Limits in the Sensitivity-Linearity Trade-off for Radio Telescope Front Ends in the HF and VHF-low Bands
- Radiometer Calibration using Machine Learning
- Detecting Cosmic 21 cm Global Signal Using an Improved Polynomial Fitting Algorithm
- External Calibrator in Global Signal Experiment for Detection of the Epoch of Reionization
- Estimating Soil Electrical Parameters in the Canadian High Arctic from Impedance Measurements of the MIST Antenna Above the Surface
- Beamforming approaches toward detecting the 21-cm global signal from Cosmic Dawn with radio array telescopes
- Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments
- System design and calibration of SITARA -- a global 21 cm short spacing interferometer prototype