Radiometer Calibration using Machine Learning
arXiv:2504.16791 · doi:10.1038/s41598-025-16732-9
Abstract
Radiometers are crucial instruments in radio astronomy, forming the primary component of nearly all radio telescopes. They measure the intensity of electromagnetic radiation, converting this radiation into electrical signals. A radiometer's primary components are an antenna and a Low Noise Amplifier (LNA), which is the core of the ``receiver'' chain. Instrumental effects introduced by the receiver are typically corrected or removed during calibration. However, impedance mismatches between the antenna and receiver can introduce unwanted signal reflections and distortions. Traditional calibration methods, such as Dicke switching, alternate the receiver input between the antenna and a well-characterised reference source to mitigate errors by comparison. Recent advances in Machine Learning (ML) offer promising alternatives. Neural networks, which are trained using known signal sources, provide a powerful means to model and calibrate complex systems where traditional analytical approaches struggle. These methods are especially relevant for detecting the faint sky-averaged 21-cm signal from atomic hydrogen at high redshifts. This is one of the main challenges in observational Cosmology today. Here, for the first time, we introduce and test a machine learning-based calibration framework capable of achieving the precision required for radiometric experiments aiming to detect the 21-cm line.
Under peer review for publication in Nature Scientific Reports as part of the Radio Astronomy collection
References in corpus (29)
- Cosmology at Low Frequencies: The 21 cm Transition and the High-Redshift Universe
- An absorption profile centred at 78 megahertz in the sky-averaged spectrum
- 21-cm cosmology
- Possible interaction between baryons and dark-matter particles revealed by the first stars
- Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps
- Concerns about Modelling of the EDGES Data
- Constraining the unexplored period between reionization and the dark ages with observations of the global 21 cm signal
- Testing for calibration systematics in the EDGES low-band data using Bayesian model selection
- SARAS 2 constraints on global 21-cm signals from the Epoch of Reionization
- SARAS 2: A Spectral Radiometer for probing Cosmic Dawn and the Epoch of Reionization through detection of the global 21 cm signal
- Calibration of the EDGES High-Band Receiver to Observe the Global 21-cm Signature from the Epoch of Reionization
- Absolute calibration of a wideband antenna and spectrometer for sky noise spectral index measurements
- A General Bayesian Framework for Foreground Modelling and Chromaticity Correction for Global 21cm Experiments
- GLOBALEMU: A novel and robust approach for emulating the sky-averaged 21-cm signal from the cosmic dawn and epoch of reionisation
- Prospects for precision cosmology with the 21 cm signal from the dark ages
- Informing antenna design for sky-averaged 21-cm experiments using a simulated Bayesian data analysis pipeline
- Bayesian noise wave calibration for 21-cm global experiments
- A Bayesian Calibration Framework for EDGES
- A Bayesian approach to modelling spectrometer data chromaticity corrected using beam factors -- I. Mathematical formalism
- SARAS CD/EoR Radiometer: Design and performance of the Digital Correlation Spectrometer
- Bayesian approach to radio frequency interference mitigation
- The effects of the antenna power pattern uncertainty within a global 21 cm experiment
- Simulation-Based Inference of the sky-averaged 21-cm signal from CD-EoR with REACH
- The EDGES measurement disfavors an excess radio background during the cosmic dawn
- Cosmic mysteries and the hydrogen 21-cm line: bridging the gap with lunar observations
- Receiver design for the REACH global 21-cm signal experiment
- Impact of extragalactic point sources on the low-frequency sky spectrum and cosmic dawn global 21-cm measurements
- FlexKnot as a Generalised Model of the Sky-averaged 21-cm Signal at z ~ 6-30 in the Presence of Systematics
- Measuring Noise Parameters Using an Open, Short, Load, and 1/8-wavelength Cable as Source Impedances