Bayesian noise wave calibration for 21-cm global experiments
arXiv:2011.14052 · doi:10.1093/mnras/stab1453
Abstract
Detection of millikelvin-level signals from the 'Cosmic Dawn' requires an unprecedented level of sensitivity and systematic calibration. We report the theory behind a novel calibration algorithm developed from the formalism introduced by the EDGES collaboration for use in 21-cm experiments. Improvements over previous approaches are provided through the incorporation of a Bayesian framework and machine learning techniques such as the use of Bayesian evidence to determine the level of frequency variation of calibration parameters that is supported by the data, the consideration of correlation between calibration parameters when determining their values and the use of a conjugate-prior based approach that results in a fast algorithm for application in the field. In self-consistency tests using empirical data models of varying complexity, our methodology is used to calibrate a 50 ambient-temperature load. The RMS error between the calibration solution and the measured temperature of the load is 8 mK, well within the 1 noise level. Whilst the methods described here are more applicable to global 21-cm experiments, they can easily be adapted and applied to other applications, including telescopes such as HERA and the SKA.
9 pages, 9 figures
References in corpus (3)
Cited by in corpus (19)
- The REACH radiometer for detecting the 21-cm hydrogen signal from redshift 7.5 to 28
- A Bayesian Calibration Framework for EDGES
- A General Bayesian Framework to Account for Foreground Map Errors in Global 21-cm Experiments
- The effects of the antenna power pattern uncertainty within a global 21 cm experiment
- Bayesian evidence-driven likelihood selection for sky-averaged 21-cm signal extraction
- RHINO: A large horn antenna for detecting the 21cm global signal
- Calibration Error in 21-centimeter Global Spectrum Experiments
- Receiver design for the REACH global 21-cm signal experiment
- RFSoC receiver calibration system for 21-cm global spectrum experiments from space: The CosmoCube case
- Measuring Noise Parameters Using an Open, Short, Load, and 1/8-wavelength Cable as Source Impedances
- Rapid and Late Cosmic Reionization Driven by Massive Galaxies: a Joint Analysis of Constraints from 21-cm, Lyman Line & CMB Data Sets
- A Bayesian Method to Mitigate the Effects of Unmodelled Time-Varying Systematics for 21-cm Cosmology Experiments
- A Bayesian approach to modelling spectrometer data chromaticity corrected using beam factors -- II. Model priors and posterior odds
- Accounting for Noise and Singularities in Bayesian Calibration Methods for Global 21-cm Cosmology Experiments
- Radiometer Calibration using Machine Learning
- Forecast measurement of the 21 cm global spectrum from Lunar orbit with the Vari-Zeroth-Order Polynomial (VZOP) method
- Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments
- The magnitude of the dark ages 21-cm signal in the context of existing early and late time constraints on CDM
- A Bayesian approach to high fidelity interferometric calibration I: mathematical formalism