3k citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Queen's UniversityCA114 papers
- TRIUMFCA110 papers
- Carleton UniversityCA107 papers
- University of AlbertaCA82 papers
- SnolabCA80 papers
- Brookhaven National LaboratoryUS71 papers
- Lawrence Berkeley National LaboratoryUS68 papers
- SLAC National Accelerator LaboratoryUS66 papers
- Stanford UniversityUS62 papers
- University of Massachusetts AmherstUS58 papers
- University of South DakotaUS58 papers
- Pacific Northwest National LaboratoryUS56 papers
72 papers · 1 filter
Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps
SuperCDMS Collaboration, M. F. Albakry, I. Alkhatib +148
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding o…
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
nEXO Collaboration, A. Anker, P. A. Breur +138
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a signif…
Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment
The DEAP Collaboration, P. Adhikari, R. Ajaj +162
In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial…
Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k
20k Collaboration, F. Acerbi, P. Adhikari +315
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity a…
Relative Measurement and Extrapolation of the Scintillation Quenching Factor of -Particles in Liquid Argon using DEAP-3600 Data
DEAP Collaboration, P. Adhikari, M. Alpízar-Venegas +101
The knowledge of scintillation quenching of -particles plays a paramount role in understanding -induced backgrounds and improving the sensitivity of liquid argon-based direct…
CUTE: A Cryogenic Underground TEst Facility at SNOLAB
Philippe Camus, Jonathan Corbett, Sean Crawford +14
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or th…
An integrated online radioassay data storage and analytics tool for nEXO
R. H. M. Tsang, A. Piepke, S. Al Kharusi +157
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in…
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
M. F. Albakry, I. Alkhatib, D. Alonso +137
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nu…
Precision Measurement of the Specific Activity of Ar in Atmospheric Argon with the DEAP-3600 Detector
P. Adhikari, R. Ajaj, M. Alpízar-Venegas +147
The specific activity of the beta decay of Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (…
Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches
20k Collaboration
The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori…
A Method to Load Tellurium in Liquid Scintillator for the Study of Neutrinoless Double Beta Decay
D. J. Auty, D. Bartlett, S. D. Biller +34
A method has been developed to load tellurium into liquid scintillator so as to permit searches for neutrinoless double beta decay with high sensitivity. The approach involves the…
EOS: a demonstrator of hybrid optical detector technology
T. Anderson, E. Anderssen, M. Askins +61
EOS is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With…
Status of the X17 search in Montreal
G. Azuelos, B. Broerman, D. Bryman +15
At the Montreal Tandem accelerator, an experiment is being set up to measure internal pair creation from the decay of nuclear excited states using a multiwire proportional chamber…
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
G. Gallina, Y. Guan, F. Retiere +162
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume,…
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
P. Agnes, I. Ahmad, S. Albergo +296
Dark matter lighter than 10 GeV/c encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50…
The level-1 trigger for the SuperCDMS experiment at SNOLAB
Jonathan S. Wilson, Hanno Meyer zu Theenhausen, Belina von Krosigk +15
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and n…
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated CF dark matter detectors
B. Ali, I. J. Arnquist, D. Baxter +54
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massi…
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
SuperCDMS Collaboration, M. F. Albakry, I. Alkhatib +126
Two photo-neutron sources, YBe and SbBe, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the…
Development of a Xe calibration source for nEXO
B. G. Lenardo, C. A. Hardy, R. H. M. Tsang +125
We study a possible calibration technique for the nEXO experiment using a Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($…
Monitoring the SNS basement neutron background with the MARS detector
COHERENT Collaboration, D. Akimov, P. An +75
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for…
The EXO-200 detector, part II: Auxiliary Systems
N. Ackerman, J. Albert, M. Auger +157
The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…
Optical calibration of the SNO+ detector in the water phase with deployed sources
SNO+ Collaboration, :, M. R. Anderson +120
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB,…
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
M. Wagenpfeil, T. Ziegler, J. Schneider +140
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work prese…
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
The DEAP Collaboration, P. Adhikari, R. Ajaj +126
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from Ar b…