The level-1 trigger for the SuperCDMS experiment at SNOLAB
arXiv:2204.13002 · doi:10.1088/1748-0221/17/07/P07010
Abstract
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, , and a 99.9% trigger efficiency for signal amplitudes of 1.1 in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.
Accepted for publication in JINST
Cited by in corpus (5)
- Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
- First demonstration of a TES based cryogenic LiMoOdetector for neutrinoless double beta decay search
- Optimum filter-based analysis for the characterization of a high-resolution magnetic microcalorimeter towards the DELight experiment
- SPLENDAQ: A Detector-Agnostic Data Acquisition System for Small-Scale Physics Experiments
- Neural-network-based level-1 trigger upgrade for the SuperCDMS experiment at SNOLAB