267 citations · 1.4k across the 47 of their papers we have counts for
26 papers · 1 filter
Development of a Modular Current-Mode NaI(Tl) Detector Array for Parity Odd (n,γ) Cross Section Measurements
J. T. Mills, J. G. Otero Munoz, K. Dickerson +26
The Neutron Optics Parity and Time-Reversal Violation Experiment (NOPTREX) Collaboration has developed a modular array of 24 NaI(Tl) detectors to measure parity and time-reversal s…
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
D. Akimov, P. An, C. Awe +75
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHER…
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
G. Gallina, Y. Guan, F. Retiere +162
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume,…
Monitoring the SNS basement neutron background with the MARS detector
COHERENT Collaboration, D. Akimov, P. An +75
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for…
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
D. Akimov, P. An, C. Awe +74
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic…
A DO detector for flux normalization of a pion decay-at-rest neutrino source
COHERENT Collaboration, D. Akimov, P. An +76
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino sou…
Development of a Kr source for the calibration of the CENNS-10 Liquid Argon Detector
COHERENT Collaboration, D. Akimov, P. An +77
We report on the preparation of and calibration measurements with a Kr source for the CENNS-10 liquid argon detector. Kr atoms generated in the de…
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
T. Stiegler, S. Sangiorgio, J. P. Brodsky +148
nEXO is a proposed tonne-scale neutrinoless double beta decay () experiment using liquid (LXe) in a Time Projection Chamber (TPC) to read out ionization and scin…
The GlueX Beamline and Detector
S. Adhikari, C. S. Akondi, H. Al Ghoul +187
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons…
A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission`
D. C. Schaper, C. Auton, L. Barrón-Palos +24
We describe a modular apparatus for use in parity-violation measurements in epithermal neutron-nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr.\ Ne…
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
P. Lv, G. F. Cao, L. J. Wen +148
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angula…
The STAR Event Plane Detector
Joseph Adams, Annika Ewigleben, Sierra Garrett +15
The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy co…
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
O. Njoya, T. Tsang, M. Tarka +153
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode…
The Central Drift Chamber for GlueX
N. S. Jarvis, C. A. Meyer, B. Zihlmann +9
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to…
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
P. Nakarmi, I. Ostrovskiy, A. K. Soma +152
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next gen…
Simulation of charge readout with segmented tiles in nEXO
Z. Li, W. R. Cen, A. Robinson +150
nEXO is a proposed experiment to search for the neutrino-less double beta decay () of Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC wil…
Developing a silica aerogel radiator for the HELIX ring-imaging Cherenkov system
Makoto Tabata, Patrick Allison, James J. Beatty +18
This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying techniqu…
Study of Silicon Photomultiplier Performance in External Electric Fields
X. L. Sun, T. Tolba, G. F. Cao +149
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
A. Jamil, T. Ziegler, P. Hufschmidt +140
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…
nEXO Pre-Conceptual Design Report
nEXO Collaboration, S. Al Kharusi, A. Alamre +171
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…
Characterization of an Ionization Readout Tile for nEXO
nEXO Collaboration, M. Jewell, A. Schubert +142
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…
High-rate axial-field ionization chamber for particle identification of radioactive beams
J. Vadas, Varinderjit Singh, G. Visser +8
The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for…
Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector
S. Yang, S. Das, B. Buck +8
A thick gas electron multiplier (THGEM) chamber with an effective readout area of 1010 cm and a 11.3 mm ionization gap has been tested along with two regular gas elec…
Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory
Benjamin Buck, Eric Anderssen, Jason Bessuille +5
We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which mak…