activity
20042026
most citedFirst Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

267 citations · 1.4k across the 47 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

26 papers · 1 filter

physics.ins-det2026

Development of a Modular Current-Mode NaI(Tl) Detector Array for Parity Odd (n,γ) Cross Section Measurements

J. T. Mills, J. G. Otero Munoz, K. Dickerson +26

The Neutron Optics Parity and Time-Reversal Violation Experiment (NOPTREX) Collaboration has developed a modular array of 24 NaI(Tl) detectors to measure parity and time-reversal s…

physics.ins-det2023

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

D. Akimov, P. An, C. Awe +75

Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHER…

physics.ins-det2022★ 26 cited

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

G. Gallina, Y. Guan, F. Retiere +162

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume,…

physics.ins-det2021★ 7 cited

Monitoring the SNS basement neutron background with the MARS detector

COHERENT Collaboration, D. Akimov, P. An +75

We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for…

physics.ins-det2021★ 4 cited

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

D. Akimov, P. An, C. Awe +74

We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic…

physics.ins-det2021★ 23 cited

A DO detector for flux normalization of a pion decay-at-rest neutrino source

COHERENT Collaboration, D. Akimov, P. An +76

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino sou…

physics.ins-det2020★ 1 cited

Development of a Kr source for the calibration of the CENNS-10 Liquid Argon Detector

COHERENT Collaboration, D. Akimov, P. An +77

We report on the preparation of and calibration measurements with a Kr source for the CENNS-10 liquid argon detector. Kr atoms generated in the de…

physics.ins-det2020★ 6 cited

Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage

T. Stiegler, S. Sangiorgio, J. P. Brodsky +148

nEXO is a proposed tonne-scale neutrinoless double beta decay () experiment using liquid (LXe) in a Time Projection Chamber (TPC) to read out ionization and scin…

physics.ins-det2020★ 99 cited

The GlueX Beamline and Detector

S. Adhikari, C. S. Akondi, H. Al Ghoul +187

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons…

physics.ins-det2020★ 8 cited

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission`

D. C. Schaper, C. Auton, L. Barrón-Palos +24

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron-nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr.\ Ne…

physics.ins-det2019★ 18 cited

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

P. Lv, G. F. Cao, L. J. Wen +148

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angula…

physics.ins-det2019★ 60 cited

The STAR Event Plane Detector

Joseph Adams, Annika Ewigleben, Sierra Garrett +15

The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy co…

physics.ins-det2019★ 18 cited

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

O. Njoya, T. Tsang, M. Tarka +153

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode…

physics.ins-det2019★ 21 cited

The Central Drift Chamber for GlueX

N. S. Jarvis, C. A. Meyer, B. Zihlmann +9

The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to…

physics.ins-det2019★ 17 cited

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon

P. Nakarmi, I. Ostrovskiy, A. K. Soma +152

Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next gen…

physics.ins-det2019★ 15 cited

Simulation of charge readout with segmented tiles in nEXO

Z. Li, W. R. Cen, A. Robinson +150

nEXO is a proposed experiment to search for the neutrino-less double beta decay () of Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC wil…

physics.ins-det2019★ 17 cited

Developing a silica aerogel radiator for the HELIX ring-imaging Cherenkov system

Makoto Tabata, Patrick Allison, James J. Beatty +18

This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying techniqu…

physics.ins-det2018★ 11 cited

Study of Silicon Photomultiplier Performance in External Electric Fields

X. L. Sun, T. Tolba, G. F. Cao +149

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…

physics.ins-det2018★ 43 cited

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

A. Jamil, T. Ziegler, P. Hufschmidt +140

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…

physics.ins-det2018★ 77 cited

nEXO Pre-Conceptual Design Report

nEXO Collaboration, S. Al Kharusi, A. Alamre +171

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…

physics.ins-det2017★ 25 cited

Characterization of an Ionization Readout Tile for nEXO

nEXO Collaboration, M. Jewell, A. Schubert +142

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…

physics.ins-det2016★ 4 cited

High-rate axial-field ionization chamber for particle identification of radioactive beams

J. Vadas, Varinderjit Singh, G. Visser +8

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for…

physics.ins-det2014★ 6 cited

Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector

S. Yang, S. Das, B. Buck +8

A thick gas electron multiplier (THGEM) chamber with an effective readout area of 1010 cm and a 11.3 mm ionization gap has been tested along with two regular gas elec…

physics.ins-det2014★ 3 cited

Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory

Benjamin Buck, Eric Anderssen, Jason Bessuille +5

We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which mak…