Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
arXiv:2111.02477
Abstract
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
arXiv commentThe version accepted by JINST. The changes made as a result of the peer review process: 1. Section 8 "Global CsI[Na] QF data fit" is expanded. The main fit result and its uncertainty is NOT CHANGED. An alternative fit is now shown in Figure 14, Figure 15 is added to further validate the assumptions in the main fit. 2. The Appendix B is restructured for clarity
References in corpus (16)
- Observation of Coherent Elastic Neutrino-Nucleus Scattering
- Semi-empirical calculation of quenching factors for ions in scintillators
- Neutrino-induced neutron spallation and supernova r-process nucleosynthesis
- Coherent neutrino-nucleus scattering detection with a CsI[Na] scintillator at the SNS spallation source
- Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches
- Neutron beam test of CsI crystal for dark matter search
- Response of CsI[Na] to Nuclear Recoils: Impact on Coherent Elastic Neutrino-Nucleus Scattering (CENS)
- First measurement of the ionization yield of nuclear recoils in liquid argon
- In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
- Comments on "First Dark Matter Results from the XENON100 Experiment"
- Liquid Scintillator Response to Proton Recoils in the 10-100 keV Range
- Quenching factor measurements of neon nuclei in neon gas
- Response of undoped cryogenic CsI to low-energy nuclear recoils
- Neutron Beam Tests of and Crystals for Dark Matter Direct Search
- High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response
- Precision analysis of the photomultiplier response to ultra low signals