The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
References in corpus (8)
- Model Independent Approach to the Single Photoelectron Calibration of Photomultiplier Tubes
- Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface
- Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs
- Characterization of the Hamamatsu R11780 12 inch Photomultiplier Tube
- DEAP-3600 Dark Matter Search
- A method for characterizing after-pulsing and dark noise of PMTs and SiPMs
- Dark Rate of a Photomultiplier at Cryogenic Temperatures
- Characterization of photomultiplier tubes with a realistic model through GPU-boosted simulation
Cited by in corpus (28)
- Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
- Design and Construction of the DEAP-3600 Dark Matter Detector
- FORMOSA: Looking Forward to Millicharged Dark Sectors
- First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector
- Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
- Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
- Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
- The liquid-argon scintillation pulseshape in DEAP-3600
- Extending light WIMP searches to single scintillation photons in LUX
- Characterization of the Hamamatsu 8" R5912-MOD Photomultiplier Tube
- Dimuons in Neutrino Telescopes: New Predictions and First Search in IceCube
- A method for characterizing after-pulsing and dark noise of PMTs and SiPMs
- Multi-site Event Discrimination in Large Liquid Scintillation Detectors
- Precision Measurement of the Specific Activity of Ar in Atmospheric Argon with the DEAP-3600 Detector
- Towards the ultimate PMT waveform analysis for neutrino and dark matter experiments
- Measurement of the relative Quantum Efficiency of Hamamatsu model R5912-20MOD photomultiplier tubes at liquid argon temperature
- Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors
- A machine learning-based methodology for pulse classification in dual-phase xenon time projection chambers
- Direct Measurement of the Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector
- Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
- PMT gain calibration and monitoring based on highly compressed hit information in KM3NeT
- Relative Measurement and Extrapolation of the Scintillation Quenching Factor of -Particles in Liquid Argon using DEAP-3600 Data
- DEAP-3600 Recent Dark Matter Results
- Using Machine Learning to Separate Cherenkov and Scintillation Light in Hybrid Neutrino Detector
- The -model under test of the SPARC database
- Development of a Kr source for the calibration of the CENNS-10 Liquid Argon Detector
- Picosecond laser test unit for photosensor characterization at ambient and low temperatures
- Characterisation of silicon photomultipliers in a dilution refrigerator down to 9.4 mK towards a cryogenic cosmic-ray muon veto system