activity
20112023
most citedFirst results from the LUX dark matter experiment at the Sanford Underground Research Facility

1.6k citations · 6.7k across the 36 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

20 papers · 1 filter

physics.ins-det2020★ 60 cited

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…

physics.ins-det2018★ 3 cited

LUX Trigger Efficiency

D. S. Akerib, S. Alsum, H. M. Araújo +94

The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this pap…

physics.ins-det2018★ 30 cited

Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

The LUX Collaboration, D. S. Akerib, S. Alsum +90

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…

physics.ins-det2017★ 43 cited

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

D. S. Akerib, S. Alsum, H. M. Araújo +95

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…

physics.ins-det2017★ 32 cited

Position Reconstruction in LUX

LUX Collaboration, D. S. Akerib, S. Alsum +91

The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…

physics.ins-det2017★ 49 cited

Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture

LUX Collaboration, D. S. Akerib, S. Alsum +91

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…

physics.ins-det2017★ 25 cited

3D Modeling of Electric Fields in the LUX Detector

LUX Collaboration, D. S. Akerib, S. Alsum +91

This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacti…

physics.ins-det2017★ 36 cited

Kr calibration of the 2013 LUX dark matter search

LUX Collaboration, D. S. Akerib, S. Alsum +91

LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…

physics.ins-det2017

LUX-ZEPLIN (LZ) Technical Design Report

B. J. Mount, S. Hans, R. Rosero +259

In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…

physics.ins-det2017★ 36 cited

Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202

The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…

physics.ins-det2016★ 50 cited

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

D. S. Akerib, S. Alsum, H. M. Araújo +98

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…

physics.ins-det2016★ 24 cited

Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics

J. R. Verbus, C. A. Rhyne, D. C. Malling +12

We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galact…

physics.ins-det2016★ 55 cited

Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

LUX Collaboration, D. S. Akerib, S. Alsum +104

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…

physics.ins-det2016★ 37 cited

Chromatographic separation of radioactive noble gases from xenon

LUX Collaboration, D. S. Akerib, H. M. Araújo +96

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…

physics.ins-det2015★ 96 cited

Tritium calibration of the LUX dark matter experiment

LUX Collaboration, D. S. Akerib, H. M. Araújo +98

We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…

physics.ins-det2015★ 14 cited

FPGA-based Trigger System for the LUX Dark Matter Experiment

D. S. Akerib, H. M. Araujo, X. Bai +100

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…

physics.ins-det2015★ 126 cited

LUX-ZEPLIN (LZ) Conceptual Design Report

The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192

The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…

physics.ins-det2012★ 334 cited

The Large Underground Xenon (LUX) Experiment

D. S. Akerib, X. Bai, S. Bedikian +91

The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMP…

physics.ins-det2012★ 49 cited

An Ultra-Low Background PMT for Liquid Xenon Detectors

D. S. Akerib, X. Bai, E. Bernard +64

Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diam…

physics.ins-det2011★ 16 cited

Radio-assay of Titanium samples for the LUX Experiment

D. S. Akerib, X. Bai, S. Bedikian +63

We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construct…