activity
19992018
most citedPlanck 2013 results. XVI. Cosmological parameters

6.6k citations · 12.3k across the 45 of their papers we have counts for

collaborators
Showing 2010Show all

9 papers · 1 filter

astro-ph.IM2010★ 13 cited

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

F. Villa, L. Terenzi, M. Sandri +71

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…

astro-ph.IM2010★ 16 cited

LFI 30 and 44 GHz receivers Back-End Modules

E. Artal, B. Aja, M. L. de la Fuente +19

The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming fr…

astro-ph.IM2010★ 24 cited

Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

R. J. Davis, A. Wilkinson, R. D. Davies +28

We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launc…

astro-ph.IM2010★ 4 cited

Advanced modelling of the Planck-LFI radiometers

P. Battaglia, C. Franceschet, A . Zonca +22

The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic m…

astro-ph.IM2010★ 10 cited

Thermal susceptibility of the Planck-LFI receivers

L Terenzi, M J Salmon, A Colin +33

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low…

astro-ph.IM2010★ 19 cited

The linearity response of the Planck-LFI flight model receivers

A. Mennella, F. Villa, L. Terenzi +37

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…

astro-ph.IM2010★ 25 cited

Planck-LFI radiometers' spectral response

A Zonca, C Franceschet, P Battaglia +22

The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Mi…

astro-ph.IM2010★ 43 cited

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

A. Mennella, M. Bersanelli, R. C. Butler +83

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…

astro-ph.CO2010★ 119 cited

Planck pre-launch status: the Planck-LFI programme

N. Mandolesi, M. Bersanelli, R. C. Butler +140

This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps…