Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
arXiv:1001.4562 · doi:10.1051/0004-6361/200912849
Abstract
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
arXiv commentAccepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)
References in corpus (18)
- Planck pre-launch status: Design and description of the Low Frequency Instrument
- Planck pre-launch status: the Planck-LFI programme
- 1/f noise and other systematic effects in the Planck-LFI radiometers
- Scanning strategy for mapping the Cosmic Microwave Background anisotropies with Planck
- Offset balancing in pseudo-correlation radiometers for CMB measurements
- Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
- PLANCK: systematic effects induced by periodic fluctuations of arbitrary shape
- Planck-LFI radiometers' spectral response
- Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
- Noise Properties of the Planck-LFI Receivers
- The linearity response of the Planck-LFI flight model receivers
- Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
- Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
- Planck-LFI radiometers tuning
- Thermal susceptibility of the Planck-LFI receivers
- Dynamic validation of the Planck/LFI thermal model
- Cryogenic environment and performance for testing the Planck radiometers
- The effect of signal digitisation in CMB experiments
Cited by in corpus (25)
- HI intensity mapping : a single dish approach
- Planck early results: first assessment of the High Frequency Instrument in-flight performance
- Planck intermediate results. XVII. Emission of dust in the diffuse interstellar medium from the far-infrared to microwave frequencies
- Planck pre-launch status: Design and description of the Low Frequency Instrument
- Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
- Planck pre-launch status: the Planck-LFI programme
- Planck 2018 results. II. Low Frequency Instrument data processing
- Planck 2015 results. III. LFI systematic uncertainties
- Planck 2013 results. II. Low Frequency Instrument data processing
- Planck Early Results. V. The Low Frequency Instrument data processing
- Planck 2013 results. V. LFI calibration
- Planck 2013 results. III. LFI systematic uncertainties
- Planck 2015 results. II. Low Frequency Instrument data processing
- Wideband 67-116 GHz receiver development for ALMA Band 2
- The linearity response of the Planck-LFI flight model receivers
- BeyondPlanck VI. Noise characterization and modelling
- Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
- The Large-Scale Polarization Explorer (LSPE)
- Thermal susceptibility of the Planck-LFI receivers
- Off-line radiometric analysis of Planck/LFI data
- BeyondPlanck X. Planck LFI frequency maps with sample-based error propagation
- In-flight calibration and verification of the Planck-LFI instrument
- Revised planet brightness temperatures using the Planck/LFI 2018 data release
- Advanced modelling of the Planck-LFI radiometers
- Effect of Fourier filters in removing periodic systematic effects from CMB data