Offset balancing in pseudo-correlation radiometers for CMB measurements
arXiv:astro-ph/0307558 · doi:10.1051/0004-6361:20031266
Abstract
Radiometeric CMB measurements need to be highly stable and this stability is best obtained with differential receivers. The residual 1/f noise in the differential output is strongly dependent on the radiometer input offset which can be cancelled using various balancing strategies. In this paper we discuss a software method implemented in the Planck-LFI pseudo-correlation receivers which uses a tunable "gain modulation factor, r, in the sky-load difference. Numerical simulations and experimental data show how proper tuning of the parameter r ensures a very stable differential output with knee frequencies of the order of few mHz. Various approaches to calculate r using the radiometer total power data are discussed with some examples relevant to Planck-LFI. Although the paper focuses on pseudo-correlation receivers and the examples are relative to Planck-LFI, the proposed method and its analysis is general and can be applied to a large class of differential radiometric receivers.
12 pages, 8 figures, accepted for publication in A&A (updated version with few editorial changes)
References in corpus (4)
Cited by in corpus (19)
- Planck pre-launch status: Design and description of the Low Frequency Instrument
- Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
- Planck 2013 results. II. Low Frequency Instrument data processing
- Planck Early Results. V. The Low Frequency Instrument data processing
- Planck 2013 results. III. LFI systematic uncertainties
- The QUIET Instrument
- Spectroscopy with Multichannel Correlation Radiometers
- Scanning strategy for mapping the Cosmic Microwave Background anisotropies with Planck
- Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
- Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
- Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
- Noise Properties of the Planck-LFI Receivers
- The linearity response of the Planck-LFI flight model receivers
- Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
- A 77-118 GHz Resonance-free Septum Polarizer
- Planck-LFI radiometers tuning
- An Integrated System at the Bleien Observatory for Mapping the Galaxy
- In-flight calibration and verification of the Planck-LFI instrument
- Effect of Fourier filters in removing periodic systematic effects from CMB data