activity
20022020
most citedPlanck 2015 results. XVI. Isotropy and statistics of the CMB

428 citations · 1.4k across the 23 of their papers we have counts for

collaborators

23 papers

astro-ph.IM2020★ 1 cited

QUBIC VII: The feedhorn-switch system of the technological demonstrator

F. Cavaliere, A. Mennella, M. Zannoni +128

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the \& Bolometric Interferometer for Cos…

astro-ph.IM2019★ 2 cited

Modelling the radiation pattern of a dual circular polarization system

S. Realini, C. Franceschet, A. Mennella

We present the electromagnetic model of a dual circular polarization antenna-feed system, consisting of a corrugated feedhorn, a polarizer and an orthomode transducer. This model w…

astro-ph.IM2017★ 43 cited

Exploring Cosmic Origins with CORE: The Instrument

P. de Bernardis, P. A. R. Ade, J. J. A. Baselmans +126

We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is…

astro-ph.CO2015★ 79 cited

Planck 2015 results. XII. Full Focal Plane simulations

Planck Collaboration, P. A. R. Ade, N. Aghanim +228

We present the 8th Full Focal Plane simulation set (FFP8), deployed in support of the Planck 2015 results. FFP8 consists of 10 fiducial mission realizations reduced to 18144 maps,…

astro-ph.CO2015★ 428 cited

Planck 2015 results. XVI. Isotropy and statistics of the CMB

Planck Collaboration, P. A. R. Ade, N. Aghanim +242

We test the statistical isotropy and Gaussianity of the cosmic microwave background (CMB) anisotropies using observations made by the Planck satellite. Our results are based mainly…

astro-ph.CO2015★ 276 cited

Planck 2015 results. IX. Diffuse component separation: CMB maps

Planck Collaboration, R. Adam, P. A. R. Ade +236

We present foreground-reduced CMB maps derived from the full Planck data set in both temperature and polarization. Compared to the corresponding Planck 2013 temperature sky maps, t…

astro-ph.IM2015★ 62 cited

Planck 2015 results. II. Low Frequency Instrument data processing

Planck Collaboration, P. A. R. Ade, N. Aghanim +213

We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our re…

astro-ph.HE2014★ 38 cited

Planck intermediate results. XXVIII. Interstellar gas and dust in the Chamaeleon clouds as seen by Fermi LAT and Planck

Planck, Fermi Collaborations, : +197

Shortened abstract: Observations of the nearby Chamaeleon clouds in gamma rays with the Fermi Large Area Telescope and in thermal dust emission with Planck and IRAS have been used…

astro-ph.GA2013★ 5 cited

Planck intermediate results. XV. A study of anomalous microwave emission in Galactic clouds

Planck Collaboration, P. A. R. Ade, N. Aghanim +180

Anomalous microwave emission (AME) is believed to be due to electric dipole radiation from small spinning dust grains. The aim of this paper is a statistical study of the basic pro…

astro-ph.IM2013★ 9 cited

Latest Progress on the QUBIC Instrument

A. Ghribi, J. Aumont, E. S. Battistelli +60

QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mi…

astro-ph.CO2011★ 1 cited

Effect of Fourier filters in removing periodic systematic effects from CMB data

F. de Gasperin, A. Mennella, D. Maino +8

We consider the application of high-pass Fourier filters to remove periodic systematic fluctuations from full-sky survey CMB datasets. We compare the filter performance with destri…

astro-ph.IM2010★ 13 cited

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

F. Villa, L. Terenzi, M. Sandri +71

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…

astro-ph.IM2010★ 16 cited

LFI 30 and 44 GHz receivers Back-End Modules

E. Artal, B. Aja, M. L. de la Fuente +19

The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming fr…

astro-ph.IM2010★ 24 cited

Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

R. J. Davis, A. Wilkinson, R. D. Davies +28

We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launc…

astro-ph.IM2010★ 19 cited

Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules

J. Varis, N. J. Hughes, M. Laaninen +26

70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and t…

astro-ph.IM2010★ 4 cited

Advanced modelling of the Planck-LFI radiometers

P. Battaglia, C. Franceschet, A . Zonca +22

The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic m…

astro-ph.IM2010★ 11 cited

Planck-LFI radiometers tuning

Francesco Cuttaia, Aniello Mennella, Luca Stringhetti +33

"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Inst…

astro-ph.IM2010★ 7 cited

Cryogenic environment and performance for testing the Planck radiometers

L. Terenzi, M. Lapolla, M. Laaninen +21

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) ha…

astro-ph.IM2010★ 19 cited

The linearity response of the Planck-LFI flight model receivers

A. Mennella, F. Villa, L. Terenzi +37

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…

astro-ph.IM2010★ 23 cited

Noise Properties of the Planck-LFI Receivers

P. Meinhold, R. Leonardi, B. Aja +47

The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of t…

astro-ph.IM2010★ 43 cited

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

A. Mennella, M. Bersanelli, R. C. Butler +83

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…

astro-ph.IM2010★ 176 cited

Planck pre-launch status: Design and description of the Low Frequency Instrument

M. Bersanelli, N. Mandolesi, R. C. Butler +109

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmi…

astro-ph2002★ 87 cited

1/f noise and other systematic effects in the Planck-LFI radiometers

Michael Seiffert, Aniello Mennella, Carlo Burigana +4

We use an analytic approach to study the susceptibility of the Planck Low Frequency Instrument radiometers to various systematic effects. We examine the effects of fluctuations in…