Abstract
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
References in corpus (9)
- Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
- Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
- Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
- LFI 30 and 44 GHz receivers Back-End Modules
- Optimized in-flight absolute calibration for extended CMB surveys
- Planck LFI flight model feed horns
- The Planck-LFI flight model composite waveguides
- The PLANCK LFI flight model ortho-mode transducers
- Advanced modelling of the Planck-LFI radiometers
Cited by in corpus (18)
- Planck 2013 results. IX. HFI spectral response
- Planck pre-launch status: Design and description of the Low Frequency Instrument
- Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
- Planck 2013 results. II. Low Frequency Instrument data processing
- Planck Early Results. V. The Low Frequency Instrument data processing
- Planck 2013 results. V. LFI calibration
- Planck 2013 results. III. LFI systematic uncertainties
- Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
- On the proper kinetic quadrupole CMB removal and the quadrupole anomalies
- BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data
- Noise Properties of the Planck-LFI Receivers
- BeyondPlanck X. Bandpass and beam leakage corrections
- Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
- BeyondPlanck X. Planck LFI frequency maps with sample-based error propagation
- Cryogenic environment and performance for testing the Planck radiometers
- Modeling the frequency response of microwave radiometers with QUCS
- Constraining the average magnetic field in galaxy clusters with current and upcoming CMB surveys
- Advanced modelling of the Planck-LFI radiometers