6.6k citations · 12.3k across the 45 of their papers we have counts for
15 papers · 1 filter
Frequency Reference Stability and Coherence Loss in Radio Astronomy Interferometers Application to the SKA
Bassem Alachkar, Althea Wilkinson, Keith Grainge
The requirements on the stability of the frequency reference in the Square Kilometre Array (SKA), as a radio astronomy interferometer, are given in terms of maximum accepted degree…
Planck 2015 results. V. LFI calibration
Planck Collaboration, P. A. R. Ade, N. Aghanim +206
We present a description of the pipeline used to calibrate the Planck Low Frequency Instrument (LFI) timelines into thermodynamic temperatures for the Planck 2015 data release, cov…
In-flight calibration and verification of the Planck-LFI instrument
Anna Gregorio, Francesco Cuttaia, Aniello Mennella +40
In this paper we discuss the Planck-LFI in-flight calibration campaign. After a brief overview of the ground test campaigns, we describe in detail the calibration and performance v…
Planck 2013 results. V. LFI calibration
Planck Collaboration, N. Aghanim, C. Armitage-Caplan +217
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the Orbital D…
Planck Early Results. V. The Low Frequency Instrument data processing
A. Zacchei, D. Maino, C. Baccigalupi +146
We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discus…
Planck Early Results. II. The thermal performance of Planck
Planck Collaboration, P. A. R. Ade, N. Aghanim +225
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative…
Planck Early Results: The Planck mission
Planck Collaboration, P. A. R. Ade, N. Aghanim +272
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in li…
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. Villa, L. Terenzi, M. Sandri +71
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…
LFI 30 and 44 GHz receivers Back-End Modules
E. Artal, B. Aja, M. L. de la Fuente +19
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming fr…
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
R. J. Davis, A. Wilkinson, R. D. Davies +28
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launc…
Advanced modelling of the Planck-LFI radiometers
P. Battaglia, C. Franceschet, A . Zonca +22
The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic m…
Thermal susceptibility of the Planck-LFI receivers
L Terenzi, M J Salmon, A Colin +33
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low…
The linearity response of the Planck-LFI flight model receivers
A. Mennella, F. Villa, L. Terenzi +37
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…
Planck-LFI radiometers' spectral response
A Zonca, C Franceschet, P Battaglia +22
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Mi…
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. Mennella, M. Bersanelli, R. C. Butler +83
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…