Abstract
This work reviews various methods used to minimize the probability of discharge occurrence in MPGDs or to mitigate the effect of spark discharges on the detector system. These include techniques that can reduce the probability that the fundamental discharge limits of MPGD structures are reached during detector operation, methods based on the HV scheme optimisation, or the implementation of resistive electrodes to enhance local discharge quenching capabilities in an amplification structure. In addition, design optimization and quality control methods to ensure stable, long-term operation of an MPGD-based detector, are considered.
3rd International Conference on Detector Stability and Aging Phenomena in Gaseous Detectors
References in corpus (7)
- The Resistive-WELL detector: a compact spark-protected single amplification-stage MPGD
- First Tests of Thick GEMs with Electrodes Made of a Resistive Kapton
- The upgrade of the ALICE TPC with GEMs and continuous readout
- Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
- Secondary discharge studies in single and multi GEM structures
- Systematic investigation of critical charge limits in Thick GEMs
- Impact of the gas choice and the geometry on the breakdown limits in Micromegas detectors