Abstract
Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron (, K, p) identification up to ~50 GeV/c. In this region Cerenkov Ring-Imaging is the most viable solution.\newline The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for PID reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield () driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas (). The detector concept is a natural extension of the PHENIX HBD detector achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.
10 pages, 15 figures
Cited by in corpus (14)
- Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
- The Thick Gas Electron Multiplier and its derivatives: physics, technologies and applications
- Design and Beam Test Results for the 2D Projective sPHENIX Electromagnetic Calorimeter Prototype
- A Study of a Mini-drift GEM Tracking Detector
- Hadron Blind Cherenkov Counters
- Evolution and Recent Developments of the Gaseous Photon Detectors Technologies
- Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC
- Study of MicroPattern Gaseous detectors with novel nanodiamond based photocathodes for single photon detection in EIC RICH
- Characteristic study of a quadruple GEM detector and its comparison with a triple GEM detector
- Study of nanodiamond photocathodes for MPGD-based detectors of single photons
- Discharge mitigation methods in MPGD-based detectors
- Progress in coupling MPGD-based Photon Detectors with Nanodiamond Photocathodes
- Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC
- The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1