An automated system to define the optimal operating settings of cryogenic calorimeters
arXiv:2007.06966 · doi:10.1016/j.nima.2021.165451
Abstract
Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.
References in corpus (23)
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- 130Te Neutrinoless Double-Beta Decay with CUORICINO
- Improved Limit on Neutrinoless Double-Beta Decay in Te with CUORE
- Searching for neutrinoless double-beta decay of Te with CUORE
- A Calorimetric Search on Double Beta Decay of 130Te
- First Result on the Neutrinoless Double Beta Decay of Se with CUPID-0
- Final result of CUPID-0 phase-I in the search for the Se Neutrinoless Double Beta Decay
- Thermal Equilibrium Calorimeters -- An Introduction
- Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
- Performances of a large mass ZnMoO4 scintillating bolometer for a next generation neutrinoless double beta decay experiment
- CUORE-0 detector: design, construction and operation
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations
- Evidence of Single State Dominance in the Two-Neutrino Double- Decay of Se-82 with CUPID-0
- The front-end electronics system for the CUORE experiment
- An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers
- A data acquisition and control system for large mass bolometer arrays
- Search of the neutrino-less double beta decay of Se into the excited states of Kr with CUPID-0
- The saga of neutrinoless double beta decay search with TeO2 thermal detectors
- A High Precision Pulse Generation and Stabilization System for Bolometric Experiments
- Phonon-mediated crystal detectors with metallic film coating capable of rejecting and events induced by surface radioactivity
- The CUORE cryostat
- Modelling the shape of thermal pulses from low temperature detectors