Thermal Equilibrium Calorimeters -- An Introduction
arXiv:physics/0503045 · doi:10.1007/10933596_1
Abstract
Near-equilibrium thermal detectors operate as classical calorimeters, with energy deposition and internal equilibration times short compared to the thermal time constant of the device. Advances in fabrication techniques, cryogenics, and electronics have made it practical to measure deposited energy with unprecedented sensitivity and precision. In this chapter we discuss performance considerations for these devices, including optimal filtering and energy resolution calculations. We begin with the basic theory of simple equilibrium calorimeters with ideal resistive thermometers. This provides a starting point for a brief discussion of electrothermal feedback, other noise sources, various non-ideal effects, and nonlinearity. We then describe other types of thermometers and show how they fit into this theoretical framework and why they may require different optimizations and figures of merit. Most of this discussion is applicable also to power detectors, or bolometers, where the detector time constants may be short compared to variations in the incident signal power.
32 pages, 10 figures, 5 tables
Cited by in corpus (15)
- Next decade of sterile neutrino studies
- A Review of X-ray Microcalorimeters Based on Superconducting Transition Edge Sensors for Astrophysics and Particle Physics
- Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements
- Magic-angle bilayer graphene nano-calorimeters -- towards broadband, energy-resolving single photon detection
- Superconducting detectors for rare event searches in experimental astroparticle physics
- Transition Edge Sensors: Physics and Applications
- Transition-Edge Sensors for cryogenic X-ray imaging spectrometers
- Slow relaxation of conductance of amorphous hopping insulators
- A Comparison of Fundamental Noise in Kinetic Inductance Detectors and Transition Edge Sensors for Millimeter-wave Applications
- An automated system to define the optimal operating settings of cryogenic calorimeters
- Modelling a Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction
- System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU
- Modelling the shape of thermal pulses from low temperature detectors
- Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
- Impact of embedded Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment