Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz
arXiv:1504.00281 · doi:10.1051/0004-6361/201526206
Abstract
We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium, otherwise strongly suppressing the LEKID response for frequencies smaller than 100~GHz. We have designed, produced and optically tested various fully multiplexed arrays based on multi-layers combinations of Aluminium (Al) and Titanium (Ti). Their sensitivities have been measured using a dedicated closed-circle 100 mK dilution cryostat and a sky simulator allowing to reproduce realistic observation conditions. The spectral response has been characterised with a Martin-Puplett interferometer up to THz frequencies, and with a resolution of 3~GHz. We demonstrate that Ti-Al LEKID can reach an optical sensitivity of about ~ (best pixel), or ~ when averaged over the whole array. The optical background was set to roughly 0.4~pW per pixel, typical for future space observatories in this particular band. The performance is close to a sensitivity of twice the CMB photon noise limit at 100~GHz which drove the design of the Planck HFI instrument. This figure remains the baseline for the next generation of millimetre-wave space satellites.
7 pages, 9 figures, submitted to A&A
References in corpus (3)
Cited by in corpus (25)
- Circuit Quantum Electrodynamics of Granular Aluminum Resonators
- Interplay between kinetic inductance, non-linearity and quasiparticle dynamics in granular aluminum MKIDs
- Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas
- Exploring Cosmic Origins with CORE: The Instrument
- Tuning microwave losses in superconducting resonators
- Development of Lumped Element Kinetic Inductance Detectors for the W-Band
- Microfabrication technology for large LEKID arrays : from NIKA2 to future applications
- LEKID sensitivity for space applications between 80 and 600 GHz
- Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz
- Calculation and measurement of critical temperature in thin superconducting multilayers
- Lumped Element Kinetic Inductance Detectors for space applications
- Exploring the performance of thin-film superconducting multilayers as Kinetic Inductance Detectors for low-frequency detection
- A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
- The KISS experiment
- The NIKA2 instrument at 30-m IRAM telescope: performance and results
- Subgap kinetic inductance detector sensitive to 85-GHz radiation
- Electromagnetic models for multilayer superconducting transmission lines
- The NIKA2 commissioning campaign: performance and first results
- KISS: a spectrometric imager for millimetre cosmology
- Suppressed-gap millimetre wave kinetic inductance detectors using DC-bias current
- Enhanced Athermal Phonon Responsivity in a Kinetic Inductance Detector with Integrated Phonon Collectors
- High-precision polarization measurements with Lumped Element Kinetic Inductance Detectors
- Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors
- On the Applicability Ranges of Tc Formulas for Proximity-Coupled Thin SN and SS Bilayers
- A millimetre-wave superconducting hyper-spectral device