Enhanced Athermal Phonon Responsivity in a Kinetic Inductance Detector with Integrated Phonon Collectors
arXiv:2601.08532 · doi:10.1063/5.0323811
Abstract
Cryogenic phonon detectors are adopted in light dark matter searches and coherent elastic neutrino-nucleus scattering experiments as they can achieve low energy thresholds. The phonon mediated sensing of silicon particle absorbers has already been proved with Kinetic Inductance Detectors (KIDs), acting both as sensors and athermal phonon absorbers. In this work we present the design and the performance of an improved detector design. In this architecture, the KID acts only as sensor and is coupled to dedicated phonon collectors. When a signal is coming from the substrate, the presence of a separated collector allows to detect an higher increase of quasi-particles density, thereby enhancing its responsivity. The meander of the KID is composed of a 77 nm trilayer wire of Aluminum-Titanium-Aluminum, while the phonon collectors are made of a 100 nm Aluminum layer and act as quasi-particles funnels. Inside the collectors, the absorbed athermal phonons generate quasi-particles which, after diffusion, are trapped in the lower-gap superconducting trilayer. The performance of this setup is compared to that of a standard phonon-mediated KID, showing an increased phonon collection efficiency by a factor of around 7.
Published version of the article
References in corpus (39)
- Observation of Coherent Elastic Neutrino-Nucleus Scattering
- WIMP dark matter candidates and searches - current status and future prospects
- First results from the CRESST-III low-mass dark matter program
- An analysis method for asymmetric resonator transmission applied to superconducting devices
- Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
- Number fluctuations of sparse quasiparticles in a superconductor
- The NIKA2 large field-of-view millimeter continuum camera for the 30-m IRAM telescope
- Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
- Evidence of a nonequilibrium distribution of quasiparticles in the microwave response of a superconducting aluminium resonator
- Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
- Coherent Neutrino Scattering with Low Temperature Bolometers at Chooz Reactor Complex
- Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
- High-speed phonon imaging using frequency-multiplexed kinetic inductance detectors
- Quasiparticle relaxation in optically excited high-Q superconducting resonators
- A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
- Normal-metal quasiparticle traps for superconducting qubits
- Gram-scale cryogenic calorimeters for rare-event searches
- Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
- Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
- Direct observation of coherent elastic antineutrino-nucleus scattering
- Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz
- Microwave-induced excess quasiparticles in superconducting resonators measured through correlated conductivity fluctuations
- A generalized proximity effect model in superconducting bi- and tri-layer films
- Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas
- Electronics and data acquisition demonstrator for a kinetic inductance camera
- Measurements and simulations of athermal phonon transmission from silicon absorbers to aluminium sensors
- Efficient quasiparticle traps with low dissipation through gap engineering
- BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
- High speed readout electronics development for frequency-multiplexed kinetic inductance detector design optimization
- Final results of CALDER: Kinetic inductance light detectors to search for rare events
- Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
- Calculation and measurement of critical temperature in thin superconducting multilayers
- Exploring the performance of thin-film superconducting multilayers as Kinetic Inductance Detectors for low-frequency detection
- The Superconducting Quasiparticle-Amplifying Transmon: A Qubit-Based Sensor for meV Scale Phonons and Single THz Photons
- Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter
- Nonequilibrium quasiparticle distribution in superconducting resonators: analytical approach
- Low-energy spectrum of the BULLKID detector array operated on surface
- Nonequilibrium quasiparticle distribution in superconducting resonators: effect of pair-breaking photons
- Germanium target sensed by phonon-mediated kinetic inductance detectors