High speed readout electronics development for frequency-multiplexed kinetic inductance detector design optimization
arXiv:1310.5891 · doi:10.1088/1748-0221/8/12/C12006
Abstract
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for spaceborne mm-wave astronomy. To optimize their design and make them insensitive to the ballistic phonons created by cosmic-ray interactions in the substrate, the phonon propagation in silicon must be studied. A dedicated fast readout electronics, using channelized Digital Down Conversion for monitoring up to 12 MKIDs over a 100MHz bandwidth was developed. Thanks to the fast ADC sampling and steep digital filtering, In-phase and Quadrature samples, having a high dynamic range, are provided at ~2 Msps. This paper describes the technical solution chosen and the results obtained.
TWEPP-13 conference at Perugia (Italy), 23-27 September 2013
References in corpus (1)
Cited by in corpus (9)
- CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
- Energy resolution and efficiency of phonon-mediated Kinetic Inductance Detectors for light detection
- The use of low temperature detectors for direct measurements of the mass of the electron neutrino
- High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
- Characterization of the KID-Based Light Detectors of CALDER
- New application of superconductors: high sensitivity cryogenic light detectors
- KISS: instrument description and performance
- Enhanced Athermal Phonon Responsivity in a Kinetic Inductance Detector with Integrated Phonon Collectors
- A millimetre-wave superconducting hyper-spectral device