Microfabrication technology for large LEKID arrays : from NIKA2 to future applications
arXiv:1601.03969 · doi:10.1007/s10909-016-1531-y
Abstract
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon) in the mm and sub-mm range. A continuing effort is ongoing to improve the microfabrication technologies and concepts in order to satisfy the requirements of new instruments. More precisely, future satellites dedicated to CMB (Cosmic Microwave Background) studies will require the same focal plane technology to cover, at least, the frequency range of 60 to 600 GHz. Aluminium LEKID developed for NIKA have so far demonstrated, under real telescope conditions, performance approaching photon-noise limitation in the band 120-300 GHz. By implementing superconducting bi-layers we recently demonstrated LEKID arrays working in the range 80-120 GHz and with sensitivities approaching the goals for CMB missions. NIKA itself (350 pixels) is followed by a more ambitious project requiring several thousands (3000-5000) pixels. NIKA2 has been installed in October 2015 at the IRAM 30-m telescope. We will describe in detail the technological improvements that allowed a relatively harmless 10-fold up-scaling in pixels count without degrading the initial sensitivity. In particular we will briefly describe a solution to simplify the difficult fabrication step linked to the slot-line propagation mode in coplanar waveguide.
References in corpus (4)
- Microwave Dielectric Loss at Single Photon Energies and milliKelvin Temperatures
- A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
- The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy
- Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz
Cited by in corpus (13)
- The NIKA2 large field-of-view millimeter continuum camera for the 30-m IRAM telescope
- The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy
- A wide field-of-view low-resolution spectrometer at APEX: instrument design and science forecast
- NIKEL_AMC: Readout electronics for the NIKA2 experiment
- Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
- Exploring Cosmic Origins with CORE: The Instrument
- High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
- Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization
- LEKID sensitivity for space applications between 80 and 600 GHz
- The NIKA2 instrument at 30-m IRAM telescope: performance and results
- The NIKA2 commissioning campaign: performance and first results
- A forecast of the sensitivity on the measurement of the optical depth to reionization with the GroundBIRD experiment
- High-precision polarization measurements with Lumped Element Kinetic Inductance Detectors