355 citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Centre National de la Recherche ScientifiqueFR102 papers
- Institut polytechnique de GrenobleFR82 papers
- Université Grenoble AlpesFR77 papers
- Commissariat à l'Énergie Atomique et aux Énergies AlternativesFR33 papers
- Institut NéelFR21 papers
- Université Joseph FourierFR20 papers
- Institut de Recherche sur les Lois Fondamentales de l'UniversFR18 papers
- Université Paris-SaclayFR18 papers
- Lyon 1 UniversitéFR17 papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR15 papers
- CEA Paris-SaclayFR14 papers
- Institut de Physique des 2 Infinis de LyonFR13 papers
14 papers · 1 filter
CUPID, the CUORE Upgrade with Particle IDentification
The CUPID Collaboration, K. Alfonso, A. Armatol +190
CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay () and other rare events using enriched Li…
Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
A. Ahmine, I. C. Bandac, A. S. Barabash +38
In preparation to the CROSS decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility…
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaboration, K. Alfonso, A. Armatol +176
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of Mo. It will operate at 10 mK…
Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
CUPID, CROSS collaborations, : +182
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS…
Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the decay search
A. Ahmine, A. Armatol, I. Bandac +24
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of Mo with macro-bolometers, due to their mod…
Optimal parameters estimation for K-edge subtraction imaging using PixiRad-2/PixieIII photon counting detector on a conventional laboratory X-ray micro-tomograph
Rémi Granger, Luc Salvo, Sabine Rolland du Roscoat +1
Photon Counting Detectors (PCDs) open new opportunities in X-ray imaging. Pixie III is a PCD using simultaneously two energy thresholds. This enables to acquire images using two di…
Resistive-nanoindentation on gold: Experiments and modeling of the electrical contact resistance
Fabien Volpi, Morgan Rusinowicz, Solène Comby-Dassonneville +5
This paper reports the experimental, analytical, and numerical study of resistive-nanoindentation tests performed on gold samples (bulk and thin film). First, the relevant contribu…
Novel technique for the study of pile-up events in cryogenic bolometers
A. Armatol, E. Armengaud, W. Armstrong +166
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such…
The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
E. Armengaud, C. Augier, A. S. Barabash +86
CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay () of Mo. In this article, we detail the CUPID-Mo detector concept, assembly, install…
CUPID pre-CDR
The CUPID Interest Group
CUPID is a proposed future tonne-scale bolometric neutrinoless double beta decay () experiment to probe the Majorana nature of neutrinos and discover Lepton Number Violation…
Comparing Image Quality in Phase Contrast sub X-Ray Tomography -- A Round-Robin Study
Simon Zabler, Maximilian Ullherr, Christian Fella +6
How to evaluate and compare image quality from different sub-micrometer (sub) CT scans? A simple test phantom made of polymer microbeads is used for recording projection images…
First scintillating bolometer tests of a CLYMENE R&D on LiMoO scintillators towards a large-scale double-beta decay experiment
G. Buşe, A. Giuliani, P. de Marcillac +10
A new R&D on lithium molybdate scintillators has begun within a project CLYMENE (Czochralski growth of LiMoO crYstals for the scintillating boloMeters used in the rare EveN…
Reflections on the projection of ions in atom probe tomography
Frédéric De Geuser, Baptiste Gault
There are two main projections used to transform, and reconstruct, field ion micrographs or atom probe tomography data into atomic coordinates at the specimen surface and, subseque…
Spatial resolution in atom probe tomography
Baptiste Gault, Michael P. Moody, Frederic de Geuser +4
This article addresses gaps in definitions and a lack of standard measurement techniques to assess the spatial resolution in atom probe tomography. This resolution is known to be a…