activity
20152025
most citedEffect of the build orientation on mechanical and electrical properties of pure Cu fabricated by E-PBF

36 citations · 86 across the 5 of their papers we have counts for

collaborators

6 papers

physics.med-ph2025★ 15 cited

Stabilizing post-yielding behavior of a stretching dominated lattice structure through microstructural optimization

Mathis Duport, Guilhem Martin, Pierre Lhuissier +3

We investigate the effect of the microstructure on the mechanical response of lattice structures made of a defect tolerant Ti-14 Mo binary alloy fabricated by Electron Powder Bed F…

physics.app-ph2023★ 17 cited

3D microstructure characterization of Cu 25Cr solid state sintered alloy using X-ray computed tomography and machine learning assisted segmentation

Lucas Varoto, Jean-Jacques Blandin, Pierre Lhuissier +4

Cu-Cr-based alloys with Cr content from 5 to 50 wt.% are widely used as electrical contacts for vacuum interrupters for medium voltage applications because of their excellent combi…

physics.med-ph2022★ 36 cited

Effect of the build orientation on mechanical and electrical properties of pure Cu fabricated by E-PBF

Alizée Thomas, Guillaume Fribourg, Jean-Jacques Blandin +3

Electrical conductors are usually made of pure copper because this material shows outstanding electrical conductivity (IACS > 100%). Additive manufacturing can be used to further i…

physics.ins-det2022★ 2 cited

Optimal parameters estimation for K-edge subtraction imaging using PixiRad-2/PixieIII photon counting detector on a conventional laboratory X-ray micro-tomograph

Rémi Granger, Luc Salvo, Sabine Rolland du Roscoat +1

Photon Counting Detectors (PCDs) open new opportunities in X-ray imaging. Pixie III is a PCD using simultaneously two energy thresholds. This enables to acquire images using two di…

physics.ins-det2019★ 16 cited

Comparing Image Quality in Phase Contrast sub X-Ray Tomography -- A Round-Robin Study

Simon Zabler, Maximilian Ullherr, Christian Fella +6

How to evaluate and compare image quality from different sub-micrometer (sub) CT scans? A simple test phantom made of polymer microbeads is used for recording projection images…

cond-mat.mtrl-sci2015

Hydrodynamic coarsening in phase-separated silicate melts

David Bouttes, Océane Lambert, Corinne Claireaux +7

Using in-situ synchrotron tomography, we investigate the coarsening dynamics of barium borosilicate melts during phase separation. The 3-D geometry of the two interconnected phases…