3k citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Laboratoire de Physique Subatomique et des Technologies AssociéesFR402 papers
- Centre National de la Recherche ScientifiqueFR383 papers
- Nantes UniversitéFR382 papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR378 papers
- Université de NantesFR348 papers
- University of MünsterDE214 papers
- University of Tennessee at KnoxvilleUS202 papers
- Kurchatov InstituteRU200 papers
- Universidade de São PauloBR199 papers
- Oak Ridge National LaboratoryUS195 papers
- Lund UniversitySE193 papers
- University of TsukubaJP189 papers
23 papers · 1 filter
SoLid: A short baseline reactor neutrino experiment
SoLid Collaboration, Y. Abreu, Y. Amhis +59
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precis…
Optimisation of the scintillation light collection and uniformity for the SoLid experiment
Y. Abreu, Y. Amhis, W. Beaumont +48
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline re…
Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
Y. Abreu, Y. Amhis, L. Arnold +48
The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288kg protot…
Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz
T. Abrahão, H. Almazan, J. C. dos Anjos +94
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is gen…
Material radioassay and selection for the XENON1T dark matter experiment
XENON Collaboration, E. Aprile, J. Aalbers +118
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessi…
A novel segmented-scintillator antineutrino detector
Y. Abreu, Y. Amhis, L. Arnold +53
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new d…
Online Rn removal by cryogenic distillation in the XENON100 experiment
XENON Collaboration, E. Aprile, J. Aalbers +119
We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purif…
Removing krypton from xenon by cryogenic distillation to the ppq level
XENON Collaboration, E. Aprile, J. Aalbers +119
The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background…
Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
The XENON Collaboration, E. Aprile, J. Aalbers +118
A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the P…
Determination of the event collision time with the ALICE detector at the LHC
ALICE Collaboration
Particle identification is an important feature of the ALICE detector at the LHC. In particular, for particle identification via the time-of-flight technique, the precise determina…
Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
Double Chooz collaboration, Y. Abe, T. Abrahão +146
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical…
Physics reach of the XENON1T dark matter experiment
The XENON collaboration, E. Aprile, J. Aalbers +113
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to…
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
G. Boireau, L. Bouvet, A. P. Collin +51
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurem…
Neutrino Physics with JUNO
Fengpeng An, Guangpeng An, Qi An +224
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hie…
Scintillation efficiency of liquid argon in low energy neutron-argon scattering
W. Creus, Y. Allkofer, C. Amsler +4
Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the…
Observation and applications of single-electron charge signals in the XENON100 experiment
E. Aprile, M. Alfonsi, K. Arisaka +77
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Intera…
First demonstration of THGEM/GAPD-matrix optical readout in two-phase Cryogenic Avalanche Detector in Ar
A. Bondar, A. Buzulutskov, A. Dolgov +5
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in A…
A liquid xenon TPC for a medical imaging Compton telescope
T. Oger, W-T. Chen, J-P. Cussonneau +10
A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order…
Material screening and selection for XENON100
XENON100 Collaboration, E. Aprile, K. Arisaka +38
Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underg…
Operation and calibration of the Silicon Drift Detectors of the ALICE experiment during the 2008 cosmic ray data taking period
B. Alessandro
The calibration and performance of the Silicon Drift Detector of the ALICE experiment during the 2008 cosmic ray run will be presented. In particular the procedures to monitor the…
Performance of prototypes for the ALICE electromagnetic calorimeter
The ALICE EMCal group
The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A array of final design mod…
The STAR Silicon Strip Detector (SSD)
L. Arnold, J. Baudot, D. Bonnet +38
The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TP…
An insulating grid spacer for large-area MICROMEGAS chambers
D. Bernard, H. Delagrange, D. G. d'Enterria +8
We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mes…