Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
arXiv:1604.06895 · doi:10.1088/1748-0221/11/08/P08001
Abstract
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
arXiv comment24 pages, 24 figures. Minor revision to be published in the Journal of Instrumentation (JINST), Corresponding author: R. Santorelli
References in corpus (15)
- Observation of electron-antineutrino disappearance at Daya Bay
- Observation of Reactor Electron Antineutrino Disappearance in the RENO Experiment
- Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment
- Measurement of a small atmospheric ratio
- Solar neutrino measurements in Super-Kamiokande-I
- Reactor electron antineutrino disappearance in the Double Chooz experiment
- Improved measurements of the neutrino mixing angle with the Double Chooz detector
- Measurement of the and Total B Solar Neutrino Fluxes with the Sudbury Neutrino Observatory Phase I Data Set
- First Measurement of θ_13 from Delayed Neutron Capture on Hydrogen in the Double Chooz Experiment
- Overview of the Jiangmen Underground Neutrino Observatory (JUNO)
- Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection
- Characterization of large area photomutipliers under low magnetic fields: design and performances of the magnetic shielding for the Double Chooz neutrino experiment
- Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment
- Development and evaluation of 10-inch Photo-Multiplier Tubes for the Double Chooz experiment
- Assembly and Installation of the Daya Bay Antineutrino Detectors
Cited by in corpus (8)
- Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors
- Search for Signatures of Sterile Neutrinos with Double Chooz
- Study of 20-inch PMTs dark count generated large pulses
- The SABRE South Technical Design Report Executive Summary
- Reactor Rate Modulation oscillation analysis with two detectors in Double Chooz
- Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz
- Statistical approach to study neutrino interactions
- Photomultiplier Requirements and Pre-Calibration for the SABRE South Liquid Scintillator Veto