Development and evaluation of 10-inch Photo-Multiplier Tubes for the Double Chooz experiment
arXiv:1104.0786 · doi:10.1016/j.nima.2011.09.023
Abstract
The goal of Double Chooz experiment is a precise measurement of the last unknown mixing angle theta_13 using two identical detectors placed at far and near sites from Chooz reactor cores. The detector is optimized for reactor-neutrino detection using specially developed 10-inch PMTs. We developed two types of measurement systems and evaluated 400 PMTs before the installation. Those PMTs fulfill our requirements, and a half of those have been installed to the far detector in 2009. The character and performance data of the PMTs are stored in a database and will be referenced in analysis and MC simulation.
Submitted to Nuclear Instruments and Methods A
References in corpus (2)
Cited by in corpus (15)
- Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment
- Reactor electron antineutrino disappearance in the Double Chooz experiment
- Improved measurements of the neutrino mixing angle with the Double Chooz detector
- First Measurement of θ_13 from Delayed Neutron Capture on Hydrogen in the Double Chooz Experiment
- The JSNS^2 Detector
- Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs
- Afterpulse Measurements of R7081 Photomultipliers for the Double Chooz Experiment
- Precision Muon Reconstruction in Double Chooz
- Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
- The Waveform Digitiser of the Double Chooz Experiment: Performance and Quantisation Effects on PhotoMultiplier Tube Signals
- A fast numerical method for photomultiplier calibration
- Monte Carlo aided design of the inner muon veto detectors for the Double Chooz experiment
- Double Chooz and a History of Reactor Theta13 Experiments
- A study of the new hemispherical 9-inch PMT
- Performance of PMTs for the JSNS2 experiment