Precision Muon Reconstruction in Double Chooz
arXiv:1405.6227 · doi:10.1016/j.nima.2014.07.058
Abstract
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.
arXiv comment12 pages, 8 figures, submitted to Nuclear Instrumentation and Methods A. Author list corrected
References in corpus (11)
- Observation of Reactor Electron Antineutrino Disappearance in the RENO Experiment
- Reactor electron antineutrino disappearance in the Double Chooz experiment
- Improved Measurement of Electron Antineutrino Disappearance at Daya Bay
- Unambiguous Determination of the Neutrino Mass Hierarchy Using Reactor Neutrinos
- The next-generation liquid-scintillator neutrino observatory LENA
- First Measurement of θ_13 from Delayed Neutron Capture on Hydrogen in the Double Chooz Experiment
- Characterization of large area photomutipliers under low magnetic fields: design and performances of the magnetic shielding for the Double Chooz neutrino experiment
- Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment
- Development and evaluation of 10-inch Photo-Multiplier Tubes for the Double Chooz experiment
- The Waveform Digitiser of the Double Chooz Experiment: Performance and Quantisation Effects on PhotoMultiplier Tube Signals
- Monte Carlo aided design of the inner muon veto detectors for the Double Chooz experiment
Cited by in corpus (7)
- Improved measurements of the neutrino mixing angle with the Double Chooz detector
- Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors
- Topological track reconstruction in unsegmented, large-volume liquid scintillator detectors
- Muon capture on light isotopes in Double Chooz
- Feasibility and physics potential of detecting B solar neutrinos at JUNO
- Muon reconstruction with a geometrical model in JUNO
- Double Chooz and a History of Reactor Theta13 Experiments