activity
20172026
most citedDark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment

915 citations · 2.9k across the 57 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

11 papers · 1 filter

physics.ins-det2025★ 1 cited

Position reconstruction and surface background model for the PandaX-4T detector

Zhicheng Qian, Linhui Gu, Chen Cheng +100

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction al…

physics.ins-det2024★ 20 cited

Signal Response Model in PandaX-4T

Yunyang Luo, Zihao Bo, Shibo Zhang +88

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of li…

physics.ins-det2022

A Gaseous Time Projection Chamber with Micromegas Readout for Low Radioactive Material Screening

Haiyan Du, Chengbo Du, Ke Han +8

Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laborator…

physics.ins-det2021★ 34 cited

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

Zhicheng Qian, Lin Si, Abdusalam Abdukerim +76

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technolo…

physics.ins-det2021★ 20 cited

Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon

Rui Yan, Zhou Wang, Xiangyi Cui +11

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and…

physics.ins-det2021★ 7 cited

Screener3D: a Gaseous Time Projection Chamber for Ultra-low Radioactive Material Screening

Haiyan Du, Chengbo Du, Karl Giboni +8

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive…

physics.ins-det2021★ 17 cited

Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector

Binbin Yan, Abdusalam Abdukerim, Wei Chen +63

We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear…

physics.ins-det2020★ 15 cited

Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal

Xiangyi Cui, Zhou Wang, Yonglin Ju +10

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experim…

physics.ins-det2020★ 16 cited

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65

We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…

physics.ins-det2018★ 21 cited

Performances of a prototype point-contact germanium detector immersed in liquid nitrogen for light dark matter search

H. Jiang, L. T. Yang, Q. Yue +70

The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China JinPing underground laboratory, where approximately 10 kg of ger…

physics.ins-det2018★ 161 cited

Dark matter direct search sensitivity of the PandaX-4T experiment

Hongguang Zhang, Abdusalam Abdukerim, Xun Chen +57

The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulat…