activity
20092022
most citedResults of a Search for Sub-GeV Dark Matter Using 2013 LUX Data

158 citations · 1.8k across the 52 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

30 papers · 1 filter

physics.ins-det2022★ 4 cited

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

LUX Collaboration, D. S. Akerib, S. Alsum +94

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability…

physics.ins-det2020★ 60 cited

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…

physics.ins-det2020★ 70 cited

Investigation of background electron emission in the LUX detector

D. S. Akerib, S. Alsum, H. M. Araújo +93

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. Whil…

physics.ins-det2020★ 43 cited

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

LUX Collaboration, D. S. Akerib, S. Alsum +94

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 20…

physics.ins-det2019★ 11 cited

Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data

The LUX Collaboration, D. S. Akerib, S. Alsum +96

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-pro…

physics.ins-det2019★ 16 cited

Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector

D. S. Akerib, S. Alsum, H. M. Araújo +98

We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from inje…

physics.ins-det2018★ 4 cited

Investigation of Amorphous Germanium Contact Properties with Planar Detectors Made from Home-Grown Germanium Crystals

W. -Z. Wei, X. -H. Meng, Y. -Y. Yang +6

The characterization of detectors fabricated from home-grown crystals is the most direct way to study crystal properties. We fabricated planar detectors from high-purity germanium…

physics.ins-det2018★ 3 cited

LUX Trigger Efficiency

D. S. Akerib, S. Alsum, H. M. Araújo +94

The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this pap…

physics.ins-det2018★ 30 cited

Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

The LUX Collaboration, D. S. Akerib, S. Alsum +90

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…

physics.ins-det2017★ 43 cited

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

D. S. Akerib, S. Alsum, H. M. Araújo +95

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…

physics.ins-det2017★ 32 cited

Position Reconstruction in LUX

LUX Collaboration, D. S. Akerib, S. Alsum +91

The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…

physics.ins-det2017★ 49 cited

Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture

LUX Collaboration, D. S. Akerib, S. Alsum +91

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…

physics.ins-det2017★ 36 cited

Kr calibration of the 2013 LUX dark matter search

LUX Collaboration, D. S. Akerib, S. Alsum +91

LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…

physics.ins-det2017★ 18 cited

Input Comparison of Radiogenic Neutron Estimates for Ultra-low Background Experiments

J. Cooley, K. J. Palladino, H. Qiu +3

Ultra-low-background experiments address some of the most important open questions in particle physics, cosmology and astrophysics: the nature of dark matter, whether the neutrino…

physics.ins-det2017

LUX-ZEPLIN (LZ) Technical Design Report

B. J. Mount, S. Hans, R. Rosero +259

In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…

physics.ins-det2017★ 36 cited

Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202

The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…

physics.ins-det2016★ 50 cited

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

D. S. Akerib, S. Alsum, H. M. Araújo +98

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…

physics.ins-det2016★ 55 cited

Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

LUX Collaboration, D. S. Akerib, S. Alsum +104

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…

physics.ins-det2016★ 37 cited

Chromatographic separation of radioactive noble gases from xenon

LUX Collaboration, D. S. Akerib, H. M. Araújo +96

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…

physics.ins-det2016★ 48 cited

Cosmogenic Activation of Materials Used in Rare Event Search Experiments

C. Zhang, D. -M. Mei, V. A. Kudryavtsev +1

We evaluate the cosmogenic production rates in some materials that are commonly used as targets and shielding/supporting components for detecting rare events. The results from Gean…

physics.ins-det2015★ 96 cited

Tritium calibration of the LUX dark matter experiment

LUX Collaboration, D. S. Akerib, H. M. Araújo +98

We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…

physics.ins-det2015★ 14 cited

FPGA-based Trigger System for the LUX Dark Matter Experiment

D. S. Akerib, H. M. Araujo, X. Bai +100

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…

physics.ins-det2015★ 126 cited

LUX-ZEPLIN (LZ) Conceptual Design Report

The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192

The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…

physics.ins-det2014★ 18 cited

Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov +79

Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and…