activity
19972021
most citedPlanck 2013 results. XVI. Cosmological parameters

6.6k citations · 28.9k across the 113 of their papers we have counts for

collaborators
Showing 2010Show all

22 papers · 1 filter

astro-ph.IM2010★ 13 cited

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

F. Villa, L. Terenzi, M. Sandri +71

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…

astro-ph.IM2010★ 4 cited

A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline

M. Frailis, M. Maris, A. Zacchei +23

The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekeeping telemetry. It is a critical component of the Planck ground…

astro-ph.IM2010★ 16 cited

LFI 30 and 44 GHz receivers Back-End Modules

E. Artal, B. Aja, M. L. de la Fuente +19

The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming fr…

astro-ph.IM2010★ 5 cited

LFI Radiometric Chain Assembly (RCA) data handling "Rachel"

M. Malaspina, E. Franceschi, P. Battaglia +26

This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221). Planck's Low Frequency Instrument is an array…

astro-ph.IM2010★ 24 cited

Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

R. J. Davis, A. Wilkinson, R. D. Davies +28

We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launc…

astro-ph.IM2010★ 12 cited

Optimization of Planck/LFI on--board data handling

M. Maris, M. Tomasi, S. Galeotta +34

To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its teleme…

astro-ph.IM2010★ 5 cited

Level 1 on-ground telemetry handling in Planck LFI

A. Zacchei, M. Frailis, M. Maris +31

The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data s…

astro-ph.IM2010★ 10 cited

The Planck-LFI flight model composite waveguides

O. D'Arcangelo, L. Figini, A. Simonetto +13

The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spannin…

astro-ph.IM2010★ 7 cited

The Planck/LFI Radiometer Electronics Box Assembly

J. M. Herreros, M. F. Gomez, R. Rebolo +12

The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was…

astro-ph.IM2010★ 10 cited

The PLANCK LFI flight model ortho-mode transducers

O. D'Arcangelo, A. Simonetto, L. Figini +10

The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70 GHz. LFI has been calibra…

astro-ph.IM2010★ 19 cited

Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules

J. Varis, N. J. Hughes, M. Laaninen +26

70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and t…

astro-ph.IM2010★ 4 cited

Advanced modelling of the Planck-LFI radiometers

P. Battaglia, C. Franceschet, A . Zonca +22

The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic m…

astro-ph.IM2010★ 10 cited

Thermal susceptibility of the Planck-LFI receivers

L Terenzi, M J Salmon, A Colin +33

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low…

astro-ph.IM2010★ 7 cited

Dynamic validation of the Planck/LFI thermal model

M. Tomasi, B. Cappellini, A. Gregorio +12

The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies…

astro-ph.IM2010★ 7 cited

Cryogenic environment and performance for testing the Planck radiometers

L. Terenzi, M. Lapolla, M. Laaninen +21

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) ha…

astro-ph.IM2010★ 10 cited

Off-line radiometric analysis of Planck/LFI data

M. Tomasi, A. Mennella, S. Galeotta +35

The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the…

astro-ph.IM2010★ 15 cited

Planck LFI flight model feed horns

F. Villa, O. D'Arcangelo, M. Pecora +10

this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced…

astro-ph.IM2010★ 19 cited

The linearity response of the Planck-LFI flight model receivers

A. Mennella, F. Villa, L. Terenzi +37

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…

astro-ph.IM2010★ 25 cited

Planck-LFI radiometers' spectral response

A Zonca, C Franceschet, P Battaglia +22

The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Mi…

astro-ph.IM2010★ 43 cited

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

A. Mennella, M. Bersanelli, R. C. Butler +83

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…

astro-ph.IM2010★ 176 cited

Planck pre-launch status: Design and description of the Low Frequency Instrument

M. Bersanelli, N. Mandolesi, R. C. Butler +109

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmi…

astro-ph.CO2010★ 119 cited

Planck pre-launch status: the Planck-LFI programme

N. Mandolesi, M. Bersanelli, R. C. Butler +140

This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps…