Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
G. Korcyl, P. Białas, C. Curceanu +36
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no…
J-PET: a new technology for the whole-body PET imaging
S. Niedźwiecki, P. Białas, C. Curceanu +30
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three…
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
R. Y. Shopa, K. Klimaszewski, P. Kowalski +30
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of…
Analysis procedure of the positronium lifetime spectra for the J-PET detector
K. Dulski, B. Zgardzinska, P. Bialas +30
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…
Time calibration of the J-PET detector
M. Skurzok, M. Silarski, D. Alfs +32
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the firs…
Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
M. Pałka, P. Strzempek, G. Korcyl +29
In this article it is presented an FPGA based ulti-oltage hreshold (MVT) system which allows of sampling fast signals ( ns rising and falling edge) in both voltage an…