244 citations · 2.6k across the 130 of their papers we have counts for
37 papers · 1 filter
Pulse-shape discrimination with machine learning for CZT detectors at the DANE beam test facility
Simone Manti, Francesco Artibani, Leonardo Abbene +36
Cadmium zinc telluride (CZT) detectors offer versatility, operational simplicity, and room-temperature X- and gamma-ray spectroscopy, making them attractive for collider applicatio…
Extended X-ray energy characterization of SIDDHARTA-2 large-area Silicon Drift Detectors up to 50 keV
Francesco Clozza, Francesco Sgaramella, Leonardo Abbene +38
The SIDDHARTA-2 experiment at the DANE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction i…
New 1mm thick Silicon Drift Detectors for future researches of Kaonic Atoms and the Pauli Exclusion principle
F. Clozza, F. Sgaramella, L. Abbene +33
Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a sensitive probe of the low-energy strong interaction via precision X-ray spectroscopy. The SIDDH…
CZT Detectors for kaonic atoms spectroscopy
Francesco Artibani, Leonardo Abbene, Antonino Buttacavoli +36
Cadmium zinc telluride (CZT) detectors offer excellent room-temperature energy resolution, making them well suited for X- and -ray spectroscopy in challenging environments. With…
Time-based Selection of Kaonic Atom X-ray Events with Quasi-Hemispherical CZT Detectors at the DAFNE collider
Francesco Artibani, Leonardo Abbene, Antonino Buttacavoli +37
This work presents the results of a time-based event selection for searching X-ray signals from kaonic atom X-ray transition using a single quasi-hemispherical Cadmium-Zinc-Telluri…
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
Y. K. Tanaka, R. Sekiya, K. Itahashi +70
A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The…
First Linearity and Stability Characterization for CZT Detection System in a ee Collider Environment
Leonardo Abbene, Francesco Artibani, Manuele Bettelli +40
The SIDDHARTA-2 collaboration built a new cadmium-zinc-telluride (CZT, CdZnTe)-based X-ray detection system, used for the first time in the DANE electron-positron collider at IN…
Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
L. Kaplon, J. Baran, N. Chug +31
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…
Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
D. Bosnar, L. Abbene, C. Amsler +39
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the…
SIDDHARTA-2 apparatus for kaonic atoms research on the DANE collider
F. Sirghi, F. Sgaramella, L. Abbene +41
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negat…
CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements
A. Scordo, L. Abbene, F. Artibani +42
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deut…
Feasibility studies for imaging ee annihilation with modular multi-strip detectors
S. Sharma, L. Povolo, S. Mariazzi +41
Studies based on imaging the annihilation of the electron (e) and its antiparticle positron (e) open up several interesting applications in nuclear medicine and fundame…
New opportunities for kaonic atoms measurements from CdZnTe detectors
L. Abbene, M. Bettelli, A. Buttacavoli +42
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution a…
J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
S. Sharma, J. Baran, R. S. Brusa +33
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…
Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy
A. Khreptak, C. Amsler, M. Bazzi +36
The SIDDHARTA-2 experiment at the DANE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong in…
First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target
A. Scordo, C. Amsler, M. Bazzi +38
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INF…
The SIDDHARTA-2 calibration method for high precision kaonic atoms X-ray spectroscopy measurements
F Sgaramella, M Miliucci, M Bazzi +29
The SIDDHARTA-2 experiment at the DANE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the…
Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider
Marco Miliucci, Massimiliano Bazzi, Damir Bosnar +30
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider…
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
P. Moskal, T. Bednarski, Sz. Niedzwiecki +36
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a…
Characterization of the SIDDHARTA-2 luminosity monitor
M. Skurzok, A. Scordo, S. Niedzwiecki +29
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and w…
The J-PET detector -- a tool for precision studies of ortho-positronium decays
K. Dulski, S. D. Bass, J. Chhokar +41
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measuremen…
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
N. G. Sharma, M. Silarski, J. Chhokar +32
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recen…
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
S. Sharma, J. Chhokar, C. Curceanu +36
Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT…
Performance assessment of the 2 positronium imaging with the total-body PET scanners
P. Moskal, D. Kisielewska, Z. Bura +39
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue,…