Tritiated methane reduction in the PandaX-4T experiment via purge and cryogenic distillation processes
Shuaijie Li, Zhou Wang, Xiangyi Cui +7
Tritium from tritiated methane (CHT) calibration is a significant impurity that restricts the sensitivity of the PandaX-4T dark matter detection experiment in the low-energy re…
Position reconstruction and surface background model for the PandaX-4T detector
Zhicheng Qian, Linhui Gu, Chen Cheng +100
We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction al…
Signal Response Model in PandaX-4T
Yunyang Luo, Zihao Bo, Shibo Zhang +88
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of li…
Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System
Xiangyi Cui, Zhou Wang, Jiafu Li +12
The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a Rn source during the onli…
Design and Operation of the PandaX-4T High Speed Ultra-high Purity Xenon Recuperation System
Zhou Wang, Wenbo Ma, Tao Zhang +10
In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultr…
Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
Zhicheng Qian, Lin Si, Abdusalam Abdukerim +76
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technolo…
Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon
Rui Yan, Zhou Wang, Xiangyi Cui +11
An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and…
Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
Binbin Yan, Abdusalam Abdukerim, Wei Chen +63
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear…
The Cryogenics and Xenon handling system for the PandaX-4T Experiment
Li Zhao, Xiangyi Cui, Wenbo Ma +5
PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon ha…
Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal
Xiangyi Cui, Zhou Wang, Yonglin Ju +10
An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experim…
Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65
We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…