420 citations · 749 across the 17 of their papers we have counts for
10 papers · 1 filter
The environmental monitoring system at the COSINE-100 experiment
H. Kim, G. Adhikari, E. Barbosa de Souza +50
The COSINE-100 experiment is designed to test the DAMA experiment which claimed an observation of a dark matter signal from an annual modulation in their residual event rate. To me…
The EXO-200 detector, part II: Auxiliary Systems
N. Ackerman, J. Albert, M. Auger +157
The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
M. Wagenpfeil, T. Ziegler, J. Schneider +140
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work prese…
The COSINE-100 Liquid Scintillator Veto System
G. Adhikari, E. Barbosa de Souza, N. Carlin +43
This paper describes the liquid scintillator veto system for the COSINE-100 dark matter experiment and its performance. The COSINE-100 detector consists of eight NaI(Tl) crystals i…
Study of Silicon Photomultiplier Performance in External Electric Fields
X. L. Sun, T. Tolba, G. F. Cao +149
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…
nEXO Pre-Conceptual Design Report
nEXO Collaboration, S. Al Kharusi, A. Alamre +171
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…
Trace radioactive impurities in final construction materials for EXO-200
D. S. Leonard, D. Auty, T. Didberidze +98
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial…
An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
200 Collaboration, C. G. Davis, C. Hall +84
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal s…
Xenon purity analysis for EXO-200 via mass spectrometry
A. Dobi, C. Hall, S. Slutsky +73
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivit…
A magnetically-driven piston pump for ultra-clean applications
F. LePort, R. Neilson, P. S. Barbeau +77
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the r…