activity
20102024
most citedSearch for Neutrinoless Double-Beta Decay in Xe with EXO-200

420 citations · 749 across the 17 of their papers we have counts for

collaborators

17 papers

nucl-ex2024

Report from the Workshop on Xenon Detector Searches: Steps Towards the Kilotonne Scale

A. Anker, A. Avasthi, M. Brodeur +35

These proceedings summarize the program and discussions of the ``Workshop on Xenon Detector Searches: Steps Towards the Kilotonne Scale'' held on October 25-27 2023 at SLAC…

nucl-ex2023★ 3 cited

'Searching for a needle in a haystack;' A Ba-tagging approach for an upgraded nEXO experiment

H. Rasiwala, K. Murray, Y. Lan +17

nEXO is a proposed experiment that will search for neutrinoless double-beta decay (0) in 5-tonnes of liquid xenon (LXe), isotopically enriched in Xe. A technique calle…

hep-ex2022★ 6 cited

Cosmogenic activation of sodium iodide

R. Saldanha, W. G. Thompson, Y. Y. Zhong +7

The production of radioactive isotopes by interactions of cosmic-ray particles with sodium iodide (NaI) crystals can produce radioactive backgrounds in detectors used to search for…

physics.ins-det2021★ 11 cited

The environmental monitoring system at the COSINE-100 experiment

H. Kim, G. Adhikari, E. Barbosa de Souza +50

The COSINE-100 experiment is designed to test the DAMA experiment which claimed an observation of a dark matter signal from an annual modulation in their residual event rate. To me…

physics.ins-det2021★ 10 cited

The EXO-200 detector, part II: Auxiliary Systems

N. Ackerman, J. Albert, M. Auger +157

The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…

physics.ins-det2021★ 12 cited

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

M. Wagenpfeil, T. Ziegler, J. Schneider +140

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work prese…

physics.ins-det2020★ 33 cited

The COSINE-100 Liquid Scintillator Veto System

G. Adhikari, E. Barbosa de Souza, N. Carlin +43

This paper describes the liquid scintillator veto system for the COSINE-100 dark matter experiment and its performance. The COSINE-100 detector consists of eight NaI(Tl) crystals i…

astro-ph.IM2019★ 51 cited

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

G. Gallina, P. Giampa, F. Retiere +148

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the develo…

physics.ins-det2018★ 11 cited

Study of Silicon Photomultiplier Performance in External Electric Fields

X. L. Sun, T. Tolba, G. F. Cao +149

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…

physics.ins-det2018★ 77 cited

nEXO Pre-Conceptual Design Report

nEXO Collaboration, S. Al Kharusi, A. Alamre +171

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…

physics.ins-det2017★ 32 cited

Trace radioactive impurities in final construction materials for EXO-200

D. S. Leonard, D. Auty, T. Didberidze +98

We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial…

physics.ins-det2016★ 10 cited

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

200 Collaboration, C. G. Davis, C. Hall +84

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal s…

nucl-ex2015★ 27 cited

Cosmogenic Backgrounds to 0νββ in EXO-200

200 Collaboration, J. B. Albert, D. J. Auty +84

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background m…

hep-ex2012★ 420 cited

Search for Neutrinoless Double-Beta Decay in Xe with EXO-200

M. Auger, D. J. Auty, P. S. Barbeau +75

We report on a search for neutrinoless double-beta decay of Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg y…

physics.ins-det2011★ 19 cited

Xenon purity analysis for EXO-200 via mass spectrometry

A. Dobi, C. Hall, S. Slutsky +73

We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivit…

physics.ins-det2011★ 19 cited

A magnetically-driven piston pump for ultra-clean applications

F. LePort, R. Neilson, P. S. Barbeau +77

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the r…

physics.atom-ph2010★ 8 cited

A simple radionuclide-driven single-ion source

M. Montero Díez, K. Twelker, W. Fairbank +54

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particl…