1.6k citations · 6.7k across the 113 of their papers we have counts for
20 papers · 1 filter
Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector
D. S. Akerib, A. K. Al Musalhi, F. Alder +208
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions.…
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
J. Aalbers, K. Abe, V. Aerne +591
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leadi…
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
The LUX-ZEPLIN, Collaboration, : +194
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of Xe is presented. LZ is a 10-tonne xenon time projection ch…
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
LUX Collaboration, D. S. Akerib, S. Alsum +94
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 20…
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
ZEPLIN Collaboration, D. S. Akerib, C. W. Akerlof +194
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)\,pb at a WIMP mass of 40 GeV/…
Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
The LUX Collaboration, D. S. Akerib, S. Alsum +96
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-pro…
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
D. S. Akerib, S. Alsum, H. M. Araújo +98
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from inje…
A Liquid Scintillation Detector for Radioassay of Gadolinium-Loaded Liquid Scintillator for the LZ Outer Detector
S. J. Haselschwardt, S. Shaw, H. N. Nelson +6
We report on the design and performance of the LUX-ZEPLIN (LZ) "Screener", a small liquid scintillator detector consisting of kg of LAB-based gadolinium-loaded liquid…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
LUX Collaboration, D. S. Akerib, S. Alsum +91
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…
Kr calibration of the 2013 LUX dark matter search
LUX Collaboration, D. S. Akerib, S. Alsum +91
LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…
LUX-ZEPLIN (LZ) Technical Design Report
B. J. Mount, S. Hans, R. Rosero +259
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
D. S. Akerib, S. Alsum, H. M. Araújo +98
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
FPGA-based Trigger System for the LUX Dark Matter Experiment
D. S. Akerib, H. M. Araujo, X. Bai +100
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…
The Large Underground Xenon (LUX) Experiment
D. S. Akerib, X. Bai, S. Bedikian +91
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMP…
An Ultra-Low Background PMT for Liquid Xenon Detectors
D. S. Akerib, X. Bai, E. Bernard +64
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diam…