437 citations · 3.6k across the 67 of their papers we have counts for
35 papers · 1 filter
EXO-200 Public Data Release for AI/ML Applications
S. Al Kharusi, G. Anton, I. Badhrees +103
We present a public release of a subset of calibration data from the EXO-200 experiment, a liquid xenon time projection chamber designed to search for neutrinoless double-beta deca…
The nEXO Radioassay Program
R. MacLellan, P. Acharya, B. Aharmim +148
Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design…
Novel High-Radiopurity Doped Amorphous Silicon Resistors for Low-Background Detectors
A. Anker, P. C. Rowson, K. Skarpaas +9
We present the results of a study of lightly doped amorphous silicon used as a resistive medium for high-radiopurity resistors in nuclear and particle physics research instrumentat…
Characterization of CRYO ASIC for charge readout in the nEXO experiment
Z. Li, M. Yu, E. Angelico +141
nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). T…
An integrated online radioassay data storage and analytics tool for nEXO
R. H. M. Tsang, A. Piepke, S. Al Kharusi +157
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in…
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
G. Gallina, Y. Guan, F. Retiere +162
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume,…
Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
A. Avasthi, T. W. Bowyer, C. Bray +31
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay () and dark m…
The EXO-200 detector, part II: Auxiliary Systems
N. Ackerman, J. Albert, M. Auger +157
The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
M. Wagenpfeil, T. Ziegler, J. Schneider +140
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work prese…
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
T. Stiegler, S. Sangiorgio, J. P. Brodsky +148
nEXO is a proposed tonne-scale neutrinoless double beta decay () experiment using liquid (LXe) in a Time Projection Chamber (TPC) to read out ionization and scin…
Measurement of the onset of nucleate boiling in liquid xenon
P. A. Breur, G. S. Ortega, P. C. Rowson +4
We report the first precision measurement of the superheat temperature required for bubble nucleation in liquid xenon of = (16.90.5) K and = (1…
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
P. Lv, G. F. Cao, L. J. Wen +148
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angula…
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
O. Njoya, T. Tsang, M. Tarka +153
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode…
Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
200 Collaboration, G. Anton, I. Badhrees +99
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and i…
Simulation of charge readout with segmented tiles in nEXO
Z. Li, W. R. Cen, A. Robinson +150
nEXO is a proposed experiment to search for the neutrino-less double beta decay () of Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC wil…
Study of Silicon Photomultiplier Performance in External Electric Fields
X. L. Sun, T. Tolba, G. F. Cao +149
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
A. Jamil, T. Ziegler, P. Hufschmidt +140
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…
nEXO Pre-Conceptual Design Report
nEXO Collaboration, S. Al Kharusi, A. Alamre +171
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
S. Delaquis, M. J. Jewell, I. Ostrovskiy +91
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position -…
Characterization of an Ionization Readout Tile for nEXO
nEXO Collaboration, M. Jewell, A. Schubert +142
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…
Trace radioactive impurities in final construction materials for EXO-200
D. S. Leonard, D. Auty, T. Didberidze +98
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial…
Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
200 Collaboration, J. B. Albert, P. S. Barbeau +84
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of c…
An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
200 Collaboration, C. G. Davis, C. Hall +84
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal s…
Investigation of radioactivity-induced backgrounds in EXO-200
J. B. Albert, D. J. Auty, P. S. Barbeau +83
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of pa…