activity
20032011
most citedPlanck pre-launch status: Design and description of the Low Frequency Instrument

176 citations · 483 across the 12 of their papers we have counts for

collaborators
Showing astro-ph.IMShow all

10 papers · 1 filter

astro-ph.IM2010★ 13 cited

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

F. Villa, L. Terenzi, M. Sandri +71

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pse…

astro-ph.IM2010★ 19 cited

Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules

J. Varis, N. J. Hughes, M. Laaninen +26

70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and t…

astro-ph.IM2010★ 4 cited

Advanced modelling of the Planck-LFI radiometers

P. Battaglia, C. Franceschet, A . Zonca +22

The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic m…

astro-ph.IM2010★ 10 cited

Thermal susceptibility of the Planck-LFI receivers

L Terenzi, M J Salmon, A Colin +33

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low…

astro-ph.IM2010★ 7 cited

Cryogenic environment and performance for testing the Planck radiometers

L. Terenzi, M. Lapolla, M. Laaninen +21

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) ha…

astro-ph.IM2010★ 19 cited

The linearity response of the Planck-LFI flight model receivers

A. Mennella, F. Villa, L. Terenzi +37

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article…

astro-ph.IM2010★ 23 cited

Noise Properties of the Planck-LFI Receivers

P. Meinhold, R. Leonardi, B. Aja +47

The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of t…

astro-ph.IM2010★ 25 cited

Planck-LFI radiometers' spectral response

A Zonca, C Franceschet, P Battaglia +22

The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Mi…

astro-ph.IM2010★ 43 cited

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

A. Mennella, M. Bersanelli, R. C. Butler +83

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters char…

astro-ph.IM2010★ 176 cited

Planck pre-launch status: Design and description of the Low Frequency Instrument

M. Bersanelli, N. Mandolesi, R. C. Butler +109

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmi…