Measurement of the refractive index and attenuation length of liquid xenon for its scintillation light
arXiv:physics/0307044 · doi:10.1016/j.nima.2003.08.117
Abstract
The attenuation length and refractive index of liquid xenon for intrinsic scintillation light (178nm) have been measured in a single experiment. The value obtained for attenuation length is 364 +- 18 mm. The refractive index is found to be 1.69 +- 0.02. Both values were measured at a temperature of 170 +- 1 K.
28 pages, 9 figures, accepted for publication in NIM A
References in corpus (1)
Cited by in corpus (32)
- Physics reach of the XENON1T dark matter experiment
- The XENON100 Dark Matter Experiment
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- Liquid noble gas detectors for low energy particle physics
- NEXO: Neutrinoless double beta decay search beyond year half-life sensitivity
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Design and Performance of the XENON10 Dark Matter Experiment
- Absorption of Scintillation Light in a 100 Liquid Xenon Ray Detector and Expected Detector Performance
- Characterization of Silicon Photomultipliers for nEXO
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
- Liquid Xe scintillation calorimetry and Xe optical properties
- Scintillation Pulse Shape Discrimination in a Two-Phase Xenon Time Projection Chamber
- Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
- Performance of a Chamber for Studying the Liquid Xenon Response to Nuclear Recoils
- Investigation of the Coincidence Resolving Time performance of a PET scanner based on liquid xenon: A Monte Carlo study
- A model of the reflection distribution in the vacuum ultra violet region
- Monte Carlo study of the Coincidence Resolving Time of a liquid xenon PET scanner, using Cherenkov radiation
- Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
- Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier
- Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light
- Measurements of Angle-Resolved Reflectivity of PTFE in Liquid Xenon with IBEX
- Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon
- A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell
- GPU-based optical simulation of the DARWIN detector
- First observation of liquid xenon electroluminescence with a Microstrip Plate
- Status and perspectives of the PETALO project
- Vacuum-Ultraviolet Absorption and Emission Spectroscopy of Gaseous, Liquid, and Supercritical Xenon
- Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon
- Leakage Tests for Am-241 Solid Sources Used for Liquid Xenon Detector Monitoring
- Electronic structure of liquid xenon in the context of light dark matter direct detection
- The DireXeno Experiment -- Measuring Correlated Scintillation Signatures in Liquid Xenon