True and apparent motion of optomechanical resonators, with applications to feedback cooling of gravitational wave detector test masses
arXiv:2408.14341 · doi:10.1103/q6z2-9qgw
Abstract
Modern optomechanical systems employ increasingly sophisticated quantum-mechanical states of light to probe and manipulate mechanical motion. Squeezed states are now used routinely to enhance the sensitivity of gravitational-wave interferometers to small external forces, and they are also used in feedback-based trapping and damping experiments on the same interferometers to enhance the achievable cooling of fluctuations in the differential test mass mode (arXiv:2102.12665). In this latter context, an accurate accounting of the true test mass motion, incorporating all sources of loss, the effect of feedback control, and the influence of classical force and sensing noises, is paramount. We work within the two-photon formalism to provide such an accounting, which extends a previously described decomposition of the quantum-mechanical noise of the light field (arxiv:2105.12052). This decomposition provides insight, rooted in physically motivated parameters, into the optimal squeezed state and feedback control configuration that should be employed to achieve the lowest fluctuations. We apply this formalism to feedback damping experiments in current and possible future gravitational-wave interferometers -- LIGO A+, LIGO Voyager, Cosmic Explorer (CE), and CE Voyager -- and discuss how these multi-degree-of-freedom systems might be compared to a single degree-of-freedom oscillator. We find that, for the oscillator definition used most commonly in the literature so far, occupation numbers below 1 are possible in these interferometers over a frequency range comparable to the bandwidth of the trapped and cooled oscillator. We also discuss several technical issues in cooling experiments with gravitational-wave detectors
arXiv comment24 pages, 8 figures
References in corpus (53)
- Cavity Optomechanics
- Advanced Virgo: a 2nd generation interferometric gravitational wave detector
- Advanced LIGO
- Introduction to Quantum Noise, Measurement and Amplification
- Towards quantum superpositions of a mirror
- A Spin Entanglement Witness for Quantum Gravity
- Gravitationally-induced entanglement between two massive particles is sufficient evidence of quantum effects in gravity
- Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
- Ground-state cooling of a micromechanical oscillator: generalized framework for cold damping and cavity-assisted cooling schemes
- Feedback-control of quantum systems using continuous state-estimation
- Large Quantum Superpositions and Interference of Massive Nanometer-Sized Objects
- Measurement-based quantum control of mechanical motion
- First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory
- Real-time optimal quantum control of mechanical motion at room temperature
- Optomechanical Cooling of a Macroscopic Oscillator by Homodyne Feedback
- Quantum noise in second generation, signal-recycled laser interferometric gravitational-wave detectors
- Squeezed light at 1550 nm with a quantum noise reduction of 12.3 dB
- Optical dilution and feedback cooling of a gram-scale oscillator to 6.9 mK
- A Cryogenic Silicon Interferometer for Gravitational-wave Detection
- Quantum Measurement Theory in Gravitational-Wave Detectors
- Tabletop experiments for quantum gravity: a user's manual
- Observable quantum entanglement due to gravity
- Characterization of systematic error in Advanced LIGO calibration
- Calibration Uncertainty for Advanced LIGO's First and Second Observing Runs
- Optimal Feedback Cooling of a Charged Levitated Nanoparticle with Adaptive Control
- Squeezed-input, optical-spring, signal-recycled gravitational-wave detectors
- Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
- Entanglement of macroscopic test masses and the Standard Quantum Limit in laser interferometry
- Optimal state estimation for cavity optomechanical systems
- Approaching the motional ground state of a 10 kg object
- Mirror quiescence and high-sensitivity position measurements with feedback
- Gravitational-wave physics with Cosmic Explorer: limits to low-frequency sensitivity
- Terrestrial Gravity Fluctuations
- Quantum limits of cold damping with optomechanical coupling
- Feedback cooling of the normal modes of a massive electromechanical system to submillikelvin temperature
- Quantum correlation of light mediated by gravity
- Overcoming detection loss and noise in squeezing-based optical sensing
- Macroscopic mechanical oscillators at the quantum limit using optomechanical cooling
- LIGOs Quantum Response to Squeezed States
- Signatures of the quantum nature of gravity in the differential motion of two masses
- Quantum state preparation and macroscopic entanglement in gravitational-wave detectors
- Towards a first design of a Newtonian-noise cancellation system for Advanced LIGO
- Observation of squeezed light in the 2 region
- Einstein-Podolsky-Rosen - entangled motion of two massive objects
- Increasing LIGO sensitivity by feedforward subtraction of auxiliary length control noise
- Generating quantum entanglement between macroscopic objects with continuous measurement and feedback control
- Quantum limit for laser interferometric gravitational wave detectors from optical dissipation
- Seismic array measurements at Virgo's West End Building for the configuration of a Newtonian-noise cancellation system
- Feasible generation of gravity-induced entanglement by using optomechanical systems
- Macroscopic quantum entanglement between an optomechanical cavity and a continuous field in presence of non-Markovian noise
- A phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers
- Joint Optimization of seismometer arrays for the cancellation of Newtonian noise from seismic body waves in the Einstein Telescope
- Unification of thermal and quantum noise in gravitational-wave detectors