Closed-loop measurements in an atom interferometer gyroscope with velocity-dependent phase-dispersion compensation
arXiv:2407.05696 · doi:10.1103/PhysRevApplied.23.044001
Abstract
Atom interferometer-based gyroscopes are expected to have a wide range of applications due to their high sensitivity. However, their dynamic range is limited by dephasing caused by velocity-dependent Sagnac phase shift in combination with the longitudinal velocity distribution of the atoms, restricting measurements of large angular velocities. In this study, we present a method for restoring the contrast deterioration in angular velocity measurements with interferometer gyroscopes using atomic beams. Our findings show that by introducing the pseudo-rotation effect with appropriate two-photon detunings for Raman lights in the interferometer, it is possible to effectively cancel the Sagnac phase shift for all atoms in the velocity distribution of the beam. Consequently, the contrast is unaffected by the rotation. Furthermore, we applied this method to an interferometer gyroscope with counter-propagating atomic beams sharing the same Raman lights. It is found that the angular velocity of the system can be estimated through the detuning point where the phase difference between the two interferometers is zero. This approach ensures that the scale factor of the atom interferometer gyroscope is independent of the change in the longitudinal velocity distribution of the atomic beam. We demonstrate our technique using the interferometer gyroscope of thermal atomic beams of rubidium-87, achieving a measurement of angular velocity of even with an acceleration of 0.68 on a three-axis rotation table. This simple and robust dispersion compensation method with Raman light detuning benefits dynamic angular velocity measurements in field applications such as the inertial navigation of vehicles.
10 pages, 5 figures
References in corpus (20)
- Measurement of the fine-structure constant as a test of the Standard Model
- Precision Measurement of the Newtonian Gravitational Constant Using Cold Atoms
- Detecting inertial effects with airborne matter-wave interferometry
- An Atomic Gravitational Wave Interferometric Sensor (AGIS)
- Atom-interferometric test of the equivalence principle at the level
- Exploring gravity with the MIGA large scale atom interferometer
- Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope
- Interleaved Atom Interferometry for High Sensitivity Inertial Measurements
- Dual Matter-Wave Inertial Sensors in Weightlessness
- Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
- Absolute airborne gravimetry with a cold atom sensor
- ZAIGA: Zhaoshan Long-baseline Atom Interferometer Gravitation Antenna
- Navigation-compatible hybrid quantum accelerometer using a Kalman filter
- Hybridizing matter-wave and classical accelerometers
- Circumventing Heisenberg's uncertainty principle in atom interferometry tests of the equivalence principle
- Twin-lattice atom interferometry
- Measuring gravity by holding atoms
- Rotation sensing with improved stability using point source atom interferometry
- Dispersion compensation in atom interferometry by a Sagnac phase
- Analyzing the sensitivity of an atom interferometer with a phase-modulation readout scheme