Compact Continuous Cold Atomic Beam from a Single Cell with 3D Cooling and Ultra-low Light Shift
arXiv:2510.13126 · doi:10.1103/drkr-8mh2
Abstract
We report a compact single-cell source of a continuous cold-atom beam with three-dimensional (3D) cooling. By integrating an off-axis moving optical molasses (OM) with a two-dimensional magneto-optical trap (MOT), we achieve simultaneous 3D cooling within a 50 mm interaction region. The source delivers a continuous flux up to 4.9(5)x10^9 atoms/s, with a transverse temperature of 94(5) microK, a longitudinal temperature as low as 231(65) microK, and a tunable mean velocity between 5 and 20 m/s. Custom in-vacuum mirrors integrate the reflective geometry for the off-axis OM beams with a 0.8 mm output aperture, ensuring stable alignment while suppressing stray light and fluorescence leakage. Ultra-low light shift and decoherence are verified via continuous Raman-Ramsey interferometry, yielding a light shift of -0.51(4)Hz and a typical fringe contrast of 90.85(30)% at a Raman separation of 100 mm (interrogation time of 8.70 ms). This compact continuous cold-atom beam source constitutes a practical building block for atomic-beam clocks and interferometers, enabling reduced aliasing noise together with improved sensitivity and accuracy for field applications.
9 pages, 11 figures
References in corpus (18)
- Logical quantum processor based on reconfigurable atom arrays
- Continuous Cold-atom Inertial Sensor with Rotation Stability
- Gravity surveys using a mobile atom interferometer
- Interleaved Atom Interferometry for High Sensitivity Inertial Measurements
- Power stabilization of a diode laser with an acousto-optic modulator
- A high-flux BEC source for mobile atom interferometers
- Continuous Bose-Einstein condensation
- Intense slow beams of bosonic potassium isotopes
- Continuous operation of a coherent 3,000-qubit system
- A continuous, sub-Doppler-cooled atomic beam interferometer for inertial sensing
- A Cold Atomic Beam Interferometer
- Advanced light-shift compensation protocol in a continuous-wave microcell atomic clock
- Photon scattering errors during stimulated Raman transitions in trapped-ion qubits
- Closed-Loop Dual-Atom-Interferometer Inertial Sensor with Continuous Cold Atomic Beams
- A compact high-flux cold atom beam source
- Closed-loop measurements in an atom interferometer gyroscope with velocity-dependent phase-dispersion compensation
- Single-Beam Magneto-Optical Trap in Back-to-Back Pyramidal and Conical Mirrors
- Equilibrium trapping of cold atoms using dipole and radiative forces in an optical trap